NTI SERIMUX SERIES CONSOLE SWITCH
51
Firmware Update
Figure 56- Firmware Update page
Under “ADMINISTRATIVE SETTINGS” , select “Firmware Update”. The Firmware Update page shows the current version of the
firmware for the Web interface (Figure 56-upper) and for the SERIMUX switch (Figure 56-lower) and enables the Administrator to
update the firmware of the SERIMUX.
WARNING: Failure to carefully follow these directions can permanently damage the SERIMUX. Please read these
directions in full before continuing. Do not, under any circumstances, reset or power-down the SERIMUX while the
firmware is being updated. Do not attempt to update the firmware if a power-failure is likely.
Note: The Firmware can only be updated from the non-secure (http) website. If you attempt to access this page from the
secure (https) website, you will be automatically redirected to the non-secure site.
To update the firmware:
1. Contact NTI for the latest firmware file and copy it to your computer.
2. On the Update Firmware page, browse to the firmware file.
3. Press
Update Web Firmware (for the Ethernet Control) or Update Switch Firmware (for the LCD)
.
Note: If an update is attempted using the wrong firmware for the section an error message will be received. No update
will occur.
4. Wait for the following message to appear (may take several minutes):
Upload Succeeded
Flash of new image completed
:
The system will automatically restart.
5. The SERIMUX will restart itself in 10 seconds, logging out all connections. After approximately 40 seconds,
the SERIMUX will be ready to resume operation.
If a message appears stating that the Upload has failed, or that a non-fatal error has occurred:
1. Ensure that the file being uploaded is the NTI firmware file.
2. Repeat the process from step 2 above.
Note: The following message does not indicate that damage to the product has occurred.
If a message appears stating that there has been a fatal error:
1.
DO NOT RESET OR POWER-DOWN THE SERIMUX
.
2. Repeat the update process from the first step 2 above.
3. If you get another Fatal Error message, call NTI tech-support at 1-800-742-8324 or 330-562-7070.
FYI: The SERIMUX should continue to run normally unless it is reset. However, damage may have occurred
to the web server firmware that will prevent the product from starting up correctly.
For updating the Web Interface,
use this section and insert the
file
serimux_eth_v1_x.bin
For updating the SERIMUX
switch, use this section and
insert the file
serimux_sw_v1_x. bin