CONTROLLER OPERATION 

 

Memory Scenes 

 
The NCM 6200 is capable of storing 128 scenes in internal memory. These scenes are completely user 
programmable and may be reprogrammed at any time. The memory scenes are organized into 16 pages of 8. 
Eight memory scene access buttons are available on the controller to bring up any of the 8 scenes within the page 
indicated on the LED display. 
 
 

Programming Memory Scenes 

 
To program a memory scene; first use the Page button to select the desired page. The channel level slide controls 
can then be moved to create the scene. To view the levels on stage, activate the Manual button before setting 
levels. Once the scene is complete, activate the Programming mode by pressing the Program button. "Pr" should 
appear in the LED display. Then press any of the eight scene select buttons to indicate which scene is to be 
programmed. 
 
 

Recalling Memory Scenes 

 
Scenes that have been programmed can be recalled at any time by pressing the desired Scene Select button 
when the proper Page is active. Pressing the button a second time will cause the scene to fade out. 
Only one memory scene can be active on an autofader at a time. Therefore, if one Scene Select button is already 
active and another is pressed a fade will occur from the first to the second. The green LED above each Scene 
Select button indicates which scene is presently active. It should be noted that memory scenes that are piled-on 
are not affected by this process and will remain on when changing Scene Select buttons. 
 

 
Scene Split 

 
The NCM 6200 has two autofaders available to the Scene Select buttons. This allows the user to have two scenes 
from the Scene Select buttons active at a time. For example, specials can be brought up and changed on one 
autofader while general lighting can remain on or be changed independently. The split where one auto fader 
begins and the other ends is determined with a Configuration mode. To configure the Scene Select buttons see 
section on CONFIGURATION MODE. 
 
 

Flash Scenes 

 
There are eight (8) user programmable Flash scenes on the NCM 6200. Pages have no effect on Flash scenes. 
Each Flash scene can be programmed to have any combination of channels bumped to full intensity when 
activated. The Scene Select buttons operate as Flash scenes whenever the controller is in Flash mode. 
 
 

Programming Flash Scenes 

 
Begin programming a Flash scene by sliding all the channel control sliders to the fully down position. Then raise all 
those that are to be on to the fully up position. To activate Flash programming, tap the Program button followed by 

Summary of Contents for NCM 6200

Page 1: ...NCM 6200 Operation Manual All information subject to change without notice February 1997 NSI Corporation PO BOX 2210 Tualatin OR 97062 Technical Service Phone 800 864 2502...

Page 2: ...he problem Follow these steps 1 Make sure the unit is in BLACKOUT 2 Tap the CONF button the display will show CF 3 Tap Memory button 4 the display will show di 4 Tap Memory button 2 the display will s...

Page 3: ...cable NOTE It is recommended that when using satellite type Dimmer Packs at least two 2 operational dimmer packs be used to power the NCM 6200 Controller Using only one Dimmer Pack may result in insuf...

Page 4: ...lower fades as the control is raised Crossfade A crossfade slide control is provided to allow manual crossfades to be performed by the operator Both memory and manual scenes may be loaded into the sli...

Page 5: ...rrent stage levels including chase effects to be locked on stage Therefore changes on the NCM 6200 will not affect stage levels It should be noted that exiting the Blind mode will instantly change sta...

Page 6: ...se Program Select chase to program FP Flash Program Select flash scene to prog CF Configure mode Select configuration no SS Scene Split Select desired scene for split Lo Program Lock Press scene 1 to...

Page 7: ...utton is already active and another is pressed a fade will occur from the first to the second The green LED above each Scene Select button indicates which scene is presently active It should be noted...

Page 8: ...sliders to full off Then tap the chase button to place the channels in memory The LED display will now show the number of the next step to be programmed Repeat the above paragraph until the desired n...

Page 9: ...e channel level is off move the slider to minimum Any further change of the slide control with now directly affect that lighting channel To release real time control of that lighting channel tap the M...

Page 10: ...show LO to indicate access to the program lock Pressing memory scene button 1 will toggle the program lock off and on as indicated by the LED display Press Blackout when done to save the lock status i...

Page 11: ...el slide controls to their minimum positions Press Config button followed by memory scene button 05 The digital display will show Sp If this is the first time you are Softpatching or you wish to erase...

Page 12: ...Set up the MIDI sequencer or other MIDI device to accept the system exclusive data and press Memory Scene 1 to start the dump When the LED display returns to normal the dump is finished Memory Scene b...

Page 13: ...hod a MIDI sequencer or advanced MIDI drum machine can be programmed to issue Program change commands to activate memory scenes chases and blackout at proper times See the MIDI implementation chart fo...

Page 14: ...hile the sequencer is recording This will cause the console to send the appropriate MIDI commands to the sequencer All main wash and flood light changes should be recorded first You can record all flo...

Page 15: ...start of system exclusive EXCLUSIVE 11110111 end of system exclusive CONTROL CHANGES TRANSMITTED CC NUMBER VALUE RANGE FUNCTION 1 1 127 FADE RATE See Chart 2 0 127 CHASE RATE See Chart 60 0 CHASE OFF...

Page 16: ...LIGHT ON NOTE ON CMD 9xH x midi chan LIGHT CHAN NO 40H 4FH CH 1 16 FULL ON VALUE 7FH 127 LIGHT OFF NOTE ON CMD 9xH x midi chan LIGHT CHAN NO 40H 4FH CH 1 16 NOTE OFF VALUE OOH CHASE SEL D FADERATE CO...

Page 17: ...K 11111000 Real time msg SYSTEM 11110000 start of system exclusive EXCLUSIVE 11110111 end of system exclusive CONTROL CHANGES ACCEPTED CONTROL NUMBER CONTROL VALUE ACTION 1 0 127 OOH 7FH Sets fade rat...

Page 18: ...previous intensity level instantly Direct Dimmer Access on Note on 0 63 1 127 Instantly causes available dimmer channel 1 64 to come to assigned level The greatest level has precedence when used toget...

Page 19: ...quires service during the warranty period NSI will repair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any authoriz...

Reviews: