SAFETY
4. Fully extend the tool while charging the HAMMER with nitrogen gas. Be sure that
the retaining pin is installed. STAY CLEAR OF TOOL POINT WHILE CHARGING.
5. Do not disassemble a HAMMER before discharging the hammer gas pre-charge.
6.
USE NITROGEN GAS ONLY!
Store and handle nitrogen tanks per OSHA
regulations.
7. Avoid high pressure fluids. Escaping fluid under pressure can penetrate the skin
causing serious injury. Relieve pressure before disconnecting hydraulic or other
lines.
8. Operate HAMMER from operator’s seat only.
9. Match HAMMER size to carrier according to NPK recommendations. The carrier
must be stable during hammer operation and during transport.
See CARRIER MACHINE COMPATIBILITY section of the NPK Service Manual.
10. Do not make any alterations to the TOOL without authorization from NPK
Engineering.
11. Use proper lifting equipment and tools when handling or servicing the HAMMER.
12. Wear ear protection and safety glasses when operating the hammer. Consult
OSHA/MSHA regulations when applicable.
13. Beware of flying metal pieces when driving Boom Pins.
14.
Do not alter the HAMMER without authorization from NPK Engineering!
15.
Use only genuine NPK replacement parts. NPK specifically disclaims any
responsibility for any damage or injury that results from the use of any tool or parts
not sold or approved by NPK.
For further safety information, consult the AEM Hydraulic Mounted Breakers Safety
Manual, AEM form MB-140 (NPK P/N H050-9600), which is furnished with every NPK
hammer. To request an additional copy, please contact NPK at 800-225-4379 or
Internet at
www.npkce.com.