NPK
- 60 -
GAS CHARGE
CHARGING THE HAMMER
USE NITROGEN GAS ONLY
STAY CLEAR OF THE TOOL WHILE
CHARGING THE HAMMER WITH GAS. The tool
may be impacted by the piston and forced out
abruptly.
PROCEDURE
1. Carry out steps 1 thru 4 of CHECKING THE GAS PRESSURE.
2. Install a pressure regulator (g7) on a
tank (g9) of nitrogen gas.
3. Connect a hose (g4) from the pressure
regulator (g7) on the nitrogen tank (g9)
to the charge adapter (g1).
4. Turn the T-handle (g2) on the charge
adapter (g1) clockwise.
5. Turn the handle (g7) on the tank
regulator counterclockwise to a fully
closed position.
Do not overtighten!
6. Open the valve (g10) on the nitrogen
tank (g9) by turning the handle
counterclockwise.
7. Slowly adjust the regulator on the nitrogen tank to the correct pressure by turning the
handle clockwise. Refer to the NITROGEN GAS PRE-CHARGE chart in the
NITROGEN GAS PRESSURE SECTION.
8. Charge the nitrogen gas, per the gas
charge decal (g11), until the pressure
gauge (g8) on the charge adapter (g1)
is at the correct setting, then turn the T-
handle (g2) counterclockwise all the
way out.
9. Close the nitrogen tank valve (g10),
then remove the hose (g4) from the
charge adapter (g1).