This installation manual must be handed to the customer and must be kept in a safe place throughout the whole period of use!
4.E.6 Technical characteristics of the control panel
The standard control panel will be the TS971 control panel.
Before installing the panel, read the enclosed manual carefully and perform the connections as indicated.
A diagram is included to facilitate the panel connections.
• Any connection that is not properly made can cause personal injury and/or irreparable damage to the product.
• The installation to which the panel is connected must comply with the low voltage regulations in force.
• Before connecting or handling the panel, it must be disconnected from the mains.
• When installing the motors and peripheral circuits, the voltage must be disconnected from the panel.
In compliance with the European Low Voltage Directive, we inform you of the following requirements:
• For permanently connected equipment, an easily accessible disconnection device must be incorporated into
the wiring.
• It is mandatory to install this equipment in an upright position and firmly attached it to the building structure.
• This equipment must always be located inside the building and in a place where it cannot be affected by water.
• The output relay contacts of this equipment should be switched to a voltage lower than 42 Vac or 60 Vdc,
depending on the type of relay used.
• This equipment may only be handled by a specialized installer, their maintenance staff or a properly trained
operator.
• The instructions for use of this equipment must always remain in the possession of the user.
The CE mark affixed to this device means that it complies with the provisions of the 2014/30/EC directives on
electromagnetic compatibility 2014/35/EU.