Pipe connector - 14” - 18” / 8” - 12” Tanks x 2
Make sure all red
clips are firmly in
place before applying
pressure
Install the connectors with
fitting as shown. Also install the
valve on the parallel adaptor.
Media:
SST60
RESIN
Media:
SST60
RESIN
Media:
A850
or
A860
RESIN
Media:
A850
or
A860
RESIN
a)
Attach the three brine grid legs to grid plate. The legs will
snap on to the tabs of the salt plate making a “click” sound.
For square brine tank there are four legs.)
c)
Drop the brine grid with brine well inside the
brine tank such that the nut fitting faces the
hole on the brine tank. Then press the grid
evenly inside the brine tank until the brine grid
legs touches the bottom of the brine tank.
b)
Insert the brine well assembly inside the grid
plate as well below.
d)
Take the brine tube and insert the nut and plastic sleeve as
shown below.
e)
Insert the tube in the float assembly elbow and hand tighten
the nut. In many cases the brine line already come installed
from the factory. Leave the other end of the brine line tube
inside the brine tank
f)
For installation of brine tank at the installation site, pull the
other end of the brine tube from the hole on the brine tank.
The completed assembly is shown below.
The hole in
the brine tank
should line up
with the brine
line as shown.
IMPORTANT:
IN ROUND
BRINE TANK, IT
IS IMPORTANT
TO ALIGN THE
HANDLE TO
THE BRINE
WELL AS
SHOWN
Insert Sleeve
Insert Sleeve inside the Tubing
6.
Attaching Brine Tubing to the Brine Line
of the Valve
*
NOTE
Resin Cleaner
An approved resin cleaner
MUST be used on a regular
basis if your water supply
contains iron.
See page 22 - Res-Up®
Feeder Installation
Instructions
ASSEMBLING BRINE TANK*
Make sure the bypass is attached well to the control valve.
Connect the straight or elbow connectors to the bypass
with red clips. Connect the inlet and outlet of the water
conditioner to the plumbing of the house. The control
valve must not be submitted to temperatures above 43°C
(110°F). When sweat fittings are used, to avoid damaging
the control valve, solder the threaded copper adapters to
the copper pipe and then, using Teflon tape, screw the
assembly into the bypass valve.
Do not use pipe thread compound as it may attack the
material in the valve body.