41.2 Configuring User Access through the
Domain
Although users do not access the domain as they use the GroupWise client, their messages often
pass through domains while traveling from one post office to another.
Section 41.2.1, “Restricting Message Size between Domains,” on page 628
Section 41.2.2, “Enabling Live Remote,” on page 629
Section 41.2.3, “Securing the Domain with SSL Connections to the MTA,” on page 629
41.2.1 Restricting Message Size between Domains
You can configure the MTA to restrict the size of messages that users are permitted to send outside
the domain.
1
In ConsoleOne, click
Tools > GroupWise Utilities > Link Configuration
.
2
Double-click the domain where you want to restrict message size.
3
In the
Maximum Send Message Size
field, specify in megabytes the size of the largest message
you want users to be able to send outside the post office.
4
If you want to delay large messages, specify the size in megabytes for message files the MTA
can process immediately in the
Delay Message Size
field.
If a message file exceeds the delay message size, the message file is moved into the low
priority (6) message queue, where only one MTA thread is allocated to process very large
Summary of Contents for GROUPWISE 7 - MESSAGE TRANSFERT AGENT
Page 2: ...604 GroupWise 7 Administration Guide novdocx en 11 December 2007...
Page 10: ...612 GroupWise 7 Administration Guide novdocx en 11 December 2007...
Page 72: ...674 GroupWise 7 Administration Guide novdocx en 11 December 2007...
Page 80: ...682 GroupWise 7 Administration Guide novdocx en 11 December 2007...