SA 2100 User Guide
45
Threshold
This value is the G force - measured in milliG (1000th of G force) to allow precise definition - which will
trigger a motion change event. When multiple thresholds are available, it is normal practice to have a
series of thresholds at different levels.
Set Time
When the threshold above is exceeded, it must remain above the threshold value for the period
specified by the corresponding Set Time (specified in milliseconds) in order to trigger an event. If the
measured time period above the threshold is less than Set Time, the event is not triggered.
Clear Time
This is the delay, in milliseconds, before an event is cleared. Once an event is triggered, it will last until
the "Max Time" (below) is reached, or a time interval equal to Clear Time has elapsed without any
readings above the threshold. A new event cannot be triggered until the previous event has been
cleared.
Max Time
This setting, measured in seconds, determines how long a single event can last. If the above-threshold
reading persists after this time period has elapsed, a new event will be triggered.
Summary of Contents for SA2100X-UG001
Page 1: ...SA2100X UG001 SA 2100 User Guide Version 2 0 August 7 2015 ...
Page 5: ...Introduction Device Description and Label Technical Specifications 1 1 ...
Page 11: ...Features and Functions LEDs Connectors Reset Button 2 7 ...
Page 24: ...SA 2100 User Guide 20 The Ready to Install the Program window opens 4 Click Install ...
Page 25: ...The Installation Progress window opens SA 2100 User Guide 21 ...
Page 92: ...Accessories Accessories List Antenna Backup Battery Power Cable USB Cable Part 6 88 ...
Page 100: ...Compliance and Regulatory General Disclaimer Warranty Information Regulatory Compliance 7 96 ...