background image

Page 12

Troubleshooting

Red LED

Blue LED

Antenna Wire

Learn
w/o Delay
Button

Delay
Potentiometer
(Time Adjustment)

Learn w/
Delay Button

DIP Switch

Terminal
Strip

Problem:  The LED on my receiver is just flickering and I’m unable to program and/or it won’t work.

Solution: You have a push plate stuck or faulty transmitter. Disconnect each push plate until the LED goes out. If LED 

does not go out, remove each transmitter battery until it does. Replace the appropriate transmitter.

Problem:  Receiver intermittently doesn’t receive the transmitter(s) signal.

Solution: You may extend the receiver antenna wire only in multiples of 6-3/4” (171), i.e. 6.75 x 4 = 27” (686) of extended 

antenna wire.

Removing Transmitter Code(s) 

Single Transmitter Code:

Ÿ

Press both Delay and No Delay Buttons simultaneously until Red LED flashes once (approximately 1 second).

Ÿ

Press transmitter button twice within 10 seconds and the transmitter code will be deleted.

All Transmitter Codes:

Ÿ

Press and hold both Delay and No Delay Buttons simultaneously until Blue LED illuminates then release (approximately 10 
seconds).

Push Plate Configuration 

1. Before beginning, it is easiest to have already prepared the installation of the push plate.
2. Connect the wires from the transmitter to the NO and COM contacts of the push plate’s switch.
3. Follow Steps 1 - 4 (Hand-Held Configuration); depress the push plate to activate the transmitter.
4. Attach the transmitter to the inside of the electrical box and complete the installation.

Hand-Held Configuration 

1. Set dip switches to the receiver to the desired activation cycle (dip switch 1 - Toggle or Pulse and dip switch 2 - 0.5s or 10s 

hold.

2. Press either Learn w/ Delay Button or Learn w/o Delay Button on the receiver depending on the activation requirements (if 

delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). Red LED on receiver will flash. After 
learn cycle is complete, adjust potentiometer to desired delay time (0 - 30 sec).

3. Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter). 

NOTE: Repeat Steps 2 - 3 to program additional transmitters.

4. To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED 

illuminates on the receiver. This indicates that the relay has been activated.

433MHz Receiver User’s Guide 

#2

OFF

ON

Description

0.5s Hold Time

10s Hold Time

Function
Relay will remain active 0.5 sec after loss of activation.
Relay will remain active 10 sec after loss of activation.

#1

OFF

ON

Description

Pulse Relay

Toggle Relay

Function
Press the transmitter once and the relay will be active 
momentarily.
Press the transmitter once and the relay output is 
active indefinitely, press it again and the relay will de-
energize indefinitely.

ON

1    2

PUL   

T

OG

0.5s     10s

ON

1    2

PUL   

T

OG

0.5s     10s

In Toggle Setting (1-ON), the 

Hold Time is inactive. Either 

setting for #2 dip switch will 

have the same result.

ON

1    2

PUL   

T

OG

0.5s     10s

0.5 second 

Pulse Setting

ON

1    2

PUL   

T

OG

0.5s     10s

10 second 

Pulse Setting

Ÿ

Always stop pedestrian traffic through the 
doorway when performing tests that may 
result in unexpected reactions by the door.

Ÿ

Ensure compliance with all applicable safety 
standards upon completion of installation.

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Summary of Contents for 5700 LEO series

Page 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Page 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Page 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Page 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Page 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Page 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Page 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Page 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Page 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Page 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Page 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Page 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Page 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Page 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Page 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Page 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Reviews: