Door Opening
Angle
Dim “A”
Dim “B”
Up to 110°
111° to 170°
12 (305)
9-1/2 (241)
13-1/4 (337)
15-3/4 (400)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in
hollow metal doors and frames is charted at the
left of this page.
• Do not scale drawing.
• Left hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges or 3/4"
(19mm) offset pivots. A separate template will
be supplied for other conditions.
• Maximum frame reveal is 7” (178mm) for this
application.
• Conduit hole nearest to hinge is suggested for
120 VAC power input.
1-11/16
(43)
1-1/4
(32)
11/16
(17.5)
1-3/4
(44)
12-15/16
(329)
7-9/16
(192)
13-7/16
(341)
3/8
(10)
C
L Hinge or Pivot
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8
(22)
(Conduit Holes -
2 Places)
Dia.
Frame
Rabbet
Frame
Stop/Soffit
A
13-13/16
(351)
1/2
(13)
B
5-1/4”
Min.
Clearance
11-11/16
(297)
3/8
(19)
14-3/16
(360)
13-13/16
(351)
Left Hand Door
open to 110° shown.
5/8
(15.9)
Stop
Sex Nuts
(2 Places)
2. Stop (Push) Side Mounting Instructions
2A. Installation Sequence
Left
Hand
Door
Right
Hand
Door
1-1/2” (38mm)
Min. Frame Face
Frame Reveal*
Door
5-1/4” (133mm)
Min. Ceiling
Clearance
1-3/4” (44mm) Min.
2-1/4” (57mm) Max.
Door Thickness
*For frame reveals less than 3" (76mm) the
arm adjusting rod can be field cut to a length
of 9-1/2" (241mm) measured from centerline
of connecting link bushing assembly.
Note: Door must be visible by person operating activation switch(es)
Step 1: Determine hand of door from illustration on upper right of this
page.
Step 2: Using template above locate and prepare holes in the frame &
door:
Frame
A. Prepare six (6) holes for 1/4-20 machine screws or No. 14 x 2-3/4"
(70mm) wood screws. Blind rivet nuts (by others) are suggested
for unreinforced hollow metal frames or for aluminum frames.
B. Concealed Wired Units Only: Two (2) 7/8" (22mm) diameter
holes for conduit, for power input and for switch/sensor wires.
NOTE: On new construction these holes will generally be drilled
by the frame supplier at their shop or at the time the frame is
installed in the wall.
Door
C. Prepare two (2) holes for 3/8" diameter sex nuts. Standard units
are supplied with sex nuts and screws for 1-3/4" (44mm) thick
door. Sex nuts and screws for other door thicknesses are
available to order.
Step 3: Remove cover from the unit and set cover & cover screws
aside.
Step 4: Mount unit to door frame. Select A or B below.
A. Concealed Wired Units Only:
B. Surface Wired Units Only:
Connect conduit to frame side of
backplate. Fasten unit to door frame (six screws).
Fasten unit to door frame (six screws).
Mount conduit bracket (found in screw pack) to unit backplate
with two screws provided. Connect wiring conduit to bracket.
Please verify desired mounting
requires Stop (Push) Side
application as shown on this
template.
Page 6
ASSA ABLOY
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9357-0008-020 (Rev 3)