Hollow Metal Door Frame Reinforcing

Frame

Material

12 Ga.

.1046 (2.66)

14 Ga.

.0747 (1.90)

16 Ga.

.0598 (1.52)

18 Ga.

.0478 (1.21)

12 Ga.

.1046 (2.66)

10 Ga.

.1343 (3.41)

10 Ga.

.1343 (3.41)

8 Ga.

.1644 (4.18)

18 Ga.

.0478 (1.21)

12 Ga.

.1046 (2.66)

12 Ga.

.1046 (2.66)

10 Ga.

.1343 (3.41)

Reinforcing

Recommended

Min. Required

Contents

General Information

•  

the 120VAC (60Hz) power input to the LEO door operator be 
supplied through normally closed alarm contacts of the alarm 
system / alarm panel.

•  Power input to LEO door operator must be 120VAC (60Hz) to 

terminals HOT and COM at terminal strip T1. Earth ground 
(GND) to green screw on backplate.

•  All wiring must conform to standard wiring practice in 

accordance with national and local wiring codes.

•  Note: Unless otherwise noted, all dimensions are given in 

inches (millimeters).

•  Minimum suggested and required material thickness for 

hollow metal frames (skin plus reinforcement) is charted on 
below.

•  Unit is Non-Handed.

•  Door must be hung on butt hinges [5” (127mm) max. width] or 

3/4” (19mm) offset pivots. A separate door and frame 
preparation template will be supplied for other conditions.

•  Door must swing freely through the entire opening and 

closing cycle before beginning the installation.

•  Use of an auxiliary door stop (by others) is always 

recommended.

•  An incorrectly installed or improperly adjusted door operator 

can cause property damage or personal injury. These 
instructions should be followed to avoid the possibility of 
misapplication or misadjustment.

UL labeled fire or smoke barrier door assemblies require that 

WARNING: Make sure 120VAC (60Hz) input power is turned 
off at facility’s main circuit breaker before proceeding with 
installation.

General Templating Information:
•  Before beginning the installation, verify that the door frame is 

properly reinforced and is well anchored in the wall.

•  Unreinforced hollow metal frames and aluminum frames 

should be prepared and fitted with 1/4-20 blind rivet nuts, 
furnished by others.

•  Concealed electrical conduit and concealed switch or sensor 

wires should be pulled to the frame before proceeding.

Fasteners for Frame:
•  1/4-20 machine screws for hollow metal and aluminum.
•  No. 14 x 2-3/4” (70mm) long sheet metal screws for wood.

Fasteners for Door:
•  1/4-20 machine screws.
•  3/8” diameter x 1-5/8” (41mm) long sex nut.

Electrical Information:
•  Maximum current draw of unit is 0.6 amps.

•  Breaker Switch protects the motor assembly and inverter; 

and has a 3 amp rating.

•  Maximum wire size is:

12AWG at terminals HOT and COM (120VAC; 60Hz) on 

“T1” Power Input Terminal.

14AWG at terminals 1 thru 4 on Accessory Terminal .
18AWG at terminals 22 thru 25 on “T1” Power Input 

Terminal.

Frame Reinforcement Table

General

2

Frame Reinforcement Table / Technical Data

2

Component Layout

3

ADA / ANSI / UL

3

Hinge (Pull) Side Mounting

4

Stop (Push) Side Mounting                                                   6 
Adjust Power and Opening / Closing Cycle

            5 / 7

Input Power Configuration

8

Final Setup

8

Inverter Details

9

Accessory / Typical Installations

10

Troubleshooting

10

RF Receiver User’s Guide            

12

Hinge (Pull) Side Template

14

Stop (Push) Side Template

15

Technical Data

120VAC, 60Hz

.6 amps

24 V DC, max. 1.1 Amp.

28 - 48" (71-122 cm)  

100-250 lb. (45-113 kg)

Input power:

Power consumption:

Power supply:

Door width:

Door weight:

Door opening angle:

Hold open time:

5 - 30 seconds (A.D.A. 5 seconds min.)

3 amps

Circuit breaker:

up to 110° Pull side; up to 170  Push side;
Manually to 180° Push/Pull side 

°

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Summary of Contents for 5700 LEO series

Page 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Page 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Page 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Page 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Page 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Page 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Page 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Page 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Page 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Page 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Page 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Page 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Page 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Page 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Page 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Page 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Reviews: