Hollow Metal Door Frame Reinforcing
Frame
Material
12 Ga.
.1046 (2.66)
14 Ga.
.0747 (1.90)
16 Ga.
.0598 (1.52)
18 Ga.
.0478 (1.21)
12 Ga.
.1046 (2.66)
10 Ga.
.1343 (3.41)
10 Ga.
.1343 (3.41)
8 Ga.
.1644 (4.18)
18 Ga.
.0478 (1.21)
12 Ga.
.1046 (2.66)
12 Ga.
.1046 (2.66)
10 Ga.
.1343 (3.41)
Reinforcing
Recommended
Min. Required
Contents
General Information
•
the 120VAC (60Hz) power input to the LEO door operator be
supplied through normally closed alarm contacts of the alarm
system / alarm panel.
• Power input to LEO door operator must be 120VAC (60Hz) to
terminals HOT and COM at terminal strip T1. Earth ground
(GND) to green screw on backplate.
• All wiring must conform to standard wiring practice in
accordance with national and local wiring codes.
• Note: Unless otherwise noted, all dimensions are given in
inches (millimeters).
• Minimum suggested and required material thickness for
hollow metal frames (skin plus reinforcement) is charted on
below.
• Unit is Non-Handed.
• Door must be hung on butt hinges [5” (127mm) max. width] or
3/4” (19mm) offset pivots. A separate door and frame
preparation template will be supplied for other conditions.
• Door must swing freely through the entire opening and
closing cycle before beginning the installation.
• Use of an auxiliary door stop (by others) is always
recommended.
• An incorrectly installed or improperly adjusted door operator
can cause property damage or personal injury. These
instructions should be followed to avoid the possibility of
misapplication or misadjustment.
UL labeled fire or smoke barrier door assemblies require that
WARNING: Make sure 120VAC (60Hz) input power is turned
off at facility’s main circuit breaker before proceeding with
installation.
General Templating Information:
• Before beginning the installation, verify that the door frame is
properly reinforced and is well anchored in the wall.
• Unreinforced hollow metal frames and aluminum frames
should be prepared and fitted with 1/4-20 blind rivet nuts,
furnished by others.
• Concealed electrical conduit and concealed switch or sensor
wires should be pulled to the frame before proceeding.
Fasteners for Frame:
• 1/4-20 machine screws for hollow metal and aluminum.
• No. 14 x 2-3/4” (70mm) long sheet metal screws for wood.
Fasteners for Door:
• 1/4-20 machine screws.
• 3/8” diameter x 1-5/8” (41mm) long sex nut.
Electrical Information:
• Maximum current draw of unit is 0.6 amps.
• Breaker Switch protects the motor assembly and inverter;
and has a 3 amp rating.
• Maximum wire size is:
12AWG at terminals HOT and COM (120VAC; 60Hz) on
“T1” Power Input Terminal.
14AWG at terminals 1 thru 4 on Accessory Terminal .
18AWG at terminals 22 thru 25 on “T1” Power Input
Terminal.
Frame Reinforcement Table
General
2
Frame Reinforcement Table / Technical Data
2
Component Layout
3
ADA / ANSI / UL
3
Hinge (Pull) Side Mounting
4
Stop (Push) Side Mounting 6
Adjust Power and Opening / Closing Cycle
5 / 7
Input Power Configuration
8
Final Setup
8
Inverter Details
9
Accessory / Typical Installations
10
Troubleshooting
10
RF Receiver User’s Guide
12
Hinge (Pull) Side Template
14
Stop (Push) Side Template
15
Technical Data
120VAC, 60Hz
.6 amps
24 V DC, max. 1.1 Amp.
28 - 48" (71-122 cm)
100-250 lb. (45-113 kg)
Input power:
Power consumption:
Power supply:
Door width:
Door weight:
Door opening angle:
Hold open time:
5 - 30 seconds (A.D.A. 5 seconds min.)
3 amps
Circuit breaker:
up to 110° Pull side; up to 170 Push side;
Manually to 180° Push/Pull side
°
ASSA ABLOY
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9357-0008-020 (Rev 3)