background image

4.  Final Electrical and Mechanical Setup Continued

E. Adjust Closing Position Magnet (See Fig. 3) - With 

door in the closed position, use finger to slide Closed 
Position Magnet so it aligns directly with the Reed 
Switch.

F. Adjust Open Position Magnet - Use fingers to slide

F cont.  Open Position Magnet 180° from Open Position 

Magnet.

G. Flip Breaker Switch to “RESET” to turn power on.  

Jump terminals 1 and 2 (as shown in Fig. 2) to 
activate door.  Note open position of the door.  Allow 
door to close.

H. Use finger to readjust the Open Position Magnet to 

desired door open position.  

I. Repeat Step G to verify door open position.  
J. Make all connections necessary for any accessories to 

the  4-position Accessory Terminal (see Pages 10-11).

K. Make necessary adjustments to inverter (see Page 9).   

Replace cover and cover screws.

Reed Switch

Closed Position 
Magnet

Open Position

Magnet

Position Ring

Figure 3

Inverter Adjustments:

Based on function 
adjustment desired, 
use table above to 
determine which POT 
is to be adjusted.

POT

FUNCTION

DESCRIPTION

OBSTR SENS 

Obstruction Detection on Open

CW - Increase
CCW - Decrease

M/DLY

Motor Delay on Opening

CW - Increase
CCW - Decrease

P1

Closing Speed

CW - Increase
CCW - Decrease

H/O TM

Hold Open Time (5 - 30 Seconds)

CW - Increase
CCW - Decrease

P2

Opening Speed

CW - Increase
CCW - Decrease

H/O TQ

Motor Torque at Hold Open 
Position

CW - Increase
CCW - Decrease

ON

1

2

WARNING

120 HIGH VOLT POTENTIAL PRESENT.   MAKE 

SURE POWER IS TURNED OFF DURING 

INSTALLATION PROCEDURE.

Dip Switch Settings

1. Door Mounting - 

2. Push Recognition - 

ON - pull
OFF - push
ON - active
OFF - inactive

WARNING

Electric

Shock Risk

(Adjustments made in the shaded 

area should be performed by 

Authorized Factory Personnel.)

L2

115Y

L1

115/230VAC IN

MOTOR OUT

L2

230Y

U

V

W

STATUS LEDS

H/O TQ

H/O TM

OBSTR

SENS

P1

M/DLY

P2

1

6

COM

SNS

COM

PB

K1

K2

11

JMP503

NC

NO

TB501

PULL  PUSH

SW501

ON

1

2

Inverter Details

Page 9 

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Summary of Contents for 5700 LEO series

Page 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Page 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Page 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Page 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Page 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Page 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Page 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Page 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Page 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Page 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Page 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Page 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Page 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Page 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Page 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Page 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Reviews: