DLV Two/Four Channel (Module 5*)
75DS2 Operations Manual
North Atlantic Industries, Inc.
11/11/2011
Rev: 2011-11-11-1000
www.naii.com
Page 23 of 43
Status, Signal Loss
Type:
binary word
Range:
N/A
Read/Write:
R
Initialized Value:
0
Check the corresponding bit for a channel’s Signal Status. A Signal input loss to that channel will trigger a bit
failure (=1) on a per channel basis. Passing status (=0). Signal Loss is indicated after 2 seconds. Signal input
monitoring is disabled during D3 or D0 Test. Any Signal Status failure, transient or intermittent, will latch the
Signal Status register. Reading any status bit will unlatch the entire register. Signal Status is part of background
testing and the status register may be checked or polled at any given time. When Status Interrupt is enabled,
Status Interrupt is reported through the
Open Status Interrupt Vector
in the General Use Memory Map.
REGISTER
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
SIGNAL STATUS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Ch2 Ch1
CHANNEL STATUS BIT
DLV Channel Frequency
Each individual channel excitation frequency is measured and the value reported to a corresponding read
register. The input excitation frequency is reported to a resolution of 1 Hz. The output is in integer decimal format.
For example
, if channel 1 input excitation is 400 Hz, the output measurement word from the corresponding
register would be 400.
DLV Set Channel Excitation Voltage
Set expected channel input Reference voltage “VREF” to a corresponding register. The input voltage is set with a
resolution of 10 mv rms. The setting is in integer decimal format.
For example
, if channel 1 expected input REF
voltage is 26.0 V
RMS
, the set word to the corresponding register would be 2600.
DLV Set Channel Signal Voltage
Set expected channel output signal voltage “VL-L” to a corresponding register. The output voltage is set with a
resolution of 10 mv rms. The setting is in integer decimal format.
For example
, if channel 1 Signal (VL-L) voltage
is to be 11.8 Vrms, the set word to the corresponding register would be 1180.