OSC (Optional Onboard Reference Supply) Set Voltage
Type:
16-bit unsigned integer
Range:
2.0 to 28.0 Vrms, or 115 Vrms
Read/Write:
R/W
Initialized Value:
N/A
Program Reference Voltage, where LSB is 0.01 Vrms.
For example:
To program 26.1 Vrms, 26.1 x 100= 2610,
which equals 0xA32. In this example, 0x0000 would be programmed in the Reference Voltage High register, and
0x0xA32 would be programmed in the Reference Voltage Low register. To program 115 Vrms, 115 x 100=
11,500, which equals 0x2CEC. In this example, 0x0000 would be programmed in the Reference Voltage High
register, and 0x2CEC would be programmed in the Reference Voltage Low register.
Note
: Reference Voltage
High register always remains at 0x0000.
REGISTER
D15
D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
0
0
81.
92
40.
96
20.
48
10.
24
5.
12
2.
56
1.
28
0.
64
0.
32
0.
16
0.
08
0.
04
0.
02
0.
01
approximate value
REF FREQUENCY LO
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D=DATA BIT (Hz)
REGISTER
D15
D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
approximate value
REF FREQUENCY HI
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D=DATA BIT (Hz)
Interrupt Vector
The Interrupt Vector Registers store the vectors for the specific interrupts generated by the module which are
used for failure reports. If the same vector is loaded into each register, the same interrupt routine will be invoked
by all interrupts. If unique vectors are loaded into the registers, a different Interrupt Service Routine (ISR) can be
invoked by each interrupt. Write 16-bit integer (0-255).
The Signal Loss interrupt vector will be serviced when the Signal Loss status is set and the interrupt has been
enabled.
The Reference Loss interrupt vector will be serviced when the Reference Loss status is set and the interrupt
has been enabled.
The BIT interrupt vector will be serviced when the Bit (failure) status is set and the interrupt has been
enabled.
The Lock Loss interrupt vector will be serviced when the Lock Loss status is set and the interrupt has been
enabled.