Introducing a VCE
1-3
Installation Manual 323-3221-291 Rel 1.0 Standard
Cabinet cover
A one-piece, three-sided cover is used on a VCE. The cover is secured by four
hex-socket screws on the front of the VCE and is designed to slide completely
off of the unit. Slots are provided in the lower-rear corners of the cover to
facilitate removal with a standard screwdriver.
Mounting options
A VCE may be installed: free-standing on the floor; with an optional Floor
Mounting Kit (Zone 2 to 4 earthquake); or with an optional Wall Mounting Kit.
A VCE is equipped with integral leveling feet for free-standing installations.
Alarm indicators
No external alarm indicators are provided on a VCE to indicate the state of
equipment mounted within a VCE, except for the 120 Vac breaker; the breaker
state can be seen on the interface panel. To view any other indications on
equipment mounted within a VCE,
the cabinet cover must be removed.
VCE components
A VCE has the following internal components (see Figure 1-2):
•
DV-45 shelf
•
power supply
•
signal and power interface panel.
Figure 1-2
VCE with cover removed
Power supply
Front
Rear
Signal interface panel
(connectorized version)
DMI-F45 module
housing
DV-45 shelf
(rear)
Leveling foot
Leveling foot