3-2 Provisioning an IPEC
555-4001-129 Standard 08.01 Novenber 2000
The following table lists the required equipment for an IPE module.
The following table lists the provisionable equipment for an IPE module and
the line cards used.
Table 2 Required equipment for an IPE module
Qty
PEC
Description
1
NT7D07BA
or
NT7D07AC
NT6D40AB
NT8D37EC
NT8D81AA
IPE module assembly:
enhanced controller card
controller card
PE power supply DC
IPE module DC
tip and ring cables (16)
2
NT8D92AB
controller to I/O cable
NTNX36DR
Cable that connects the MCTM, MCTM-I,
MCRM, MCRM-S, MNET, and MLNK to the
IPE.
Note: MCTM, MCRM, MNET, and MLNK
have been manufacture discontinued but are
still supported in the field.
Table 3 Provisionable equipment for an IPE module (Sheet 1 of 2)
Qty
PEC
Description
NT8D02
DLC-16 port IVD Digital Line Card
NT8D03
16 port analog line card
NT8D09
MLC-16 port analog (500/2500) with Message
Waiting feature
NT5D11
LTI-24 port analog T-1 interface card
Note: Occupies 2 consecutive slots-cannot
be installed in slot 7 or 15
NT5D51
Meridian Integrated Conference Bridge
(MICBII)
NTQR02AA
Meridian HomeOffice II (MHOII Release 2)