Provisioning an IPEC 3-7
Meridian SuperNode MSL-100 Intelligent Peripheral Equipment (IPE) Reference Manual MSL14
Figure 4 Connection between MCRM-S and remote nodes
Mounting and bracing kits
In some cases, floor mounting or bracing kits are required for extra stability.
Installations on raised computer floors do not require mounting kits. However,
in earthquake risk areas, cube bracing is required. See the “Installation in
earthquake risk areas" section.
Installations in non-earthquake risk areas
For installations on concrete floors in non-earthquake risk areas, the standard
concrete floor mounting kit (NT8D64BF) is required. This kit can be used
with either the newer (ac/dc) global pedestal or the older pedestal with the
NT7D10 dc-powered power distribution unit (PDU).
Installation in earthquake risk areas
For installations on concrete floors in earthquake risk areas, the seismic
concrete floor mounting kit (NT8D64BE) is required. For installations on
raised computer floors, the following cube bracing kits are required:
•
IPECs with two modules require cube bracing kit NT8D64CA
•
IPECs with three modules require cube bracing kit NT8D64CB
•
IPECs with three modules require cube bracing kit NT8D64CC
•
existing installations of two or three modules require cube bracing
expansion kit NT8D64CD when one additional module is added
Note: These kits require the newer ac/dc global pedestal.
SL-100 Host
RCC2
ESA
Inter-module Links
MCRM-S
RMM
DLM
LCME
IPE
RLCM/RDLM
Trunks
IVD
POTS
ISDN
IVD
POTS
DS1
LAN/WAN
downloading
Serial monitor port