Page 72 of 136
Chapter 7 — Meridian Modular Telephones
553-3121-100
Standard 2.0
September 1998
The Power Supply Board comes factory installed with any configuration of
the M2016S and M2216ACD-2. The M2006 and M2008 require the Power
Supply Board with the addition of any option. The M2616 requires the Power
Supply Board with any option except the Display Module.
Local plug-in transformer
A single winding transformer equipped with a 10 ft. (3 m) cord of 22 AWG
two-conductor stranded and twisted wire with a modular RJ-11 duplex
adapter (Refer to
) can provide the additional power
needed to operate the telephone and its options.
120 V transformer (AO367335 or equivalent)
The following minimum specifications must be met by this transformer:
•
Input voltage
120 V AC / 60 Hz
•
No load output voltage
29 V AC maximum
•
Voltage at rated current
26.7 V AC minimum
•
Rated load current
700 mA
240 V transformer (AO367914 or equivalent)
The following minimum specifications have to be met by this transformer:
•
Input voltage
240 V AC / 50 Hz
•
No load output voltage
29 V AC maximum
CAUTION
Do not plug any equipment (computer, modem, LAN card) other than
the Meridian Modular Telephone into the RJ-11 transformer adapter,
as damage to equipment may result.
Summary of Contents for Meridian 1 Option 11C Compact
Page 3: ...553 3121 100 Standard 2 0 September 1998 ...
Page 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Page 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Page 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Page 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Page 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Page 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...