Chapter 7 — Meridian Modular Telephones
Page 71 of 136
Meridian 1 Option 11C Compact
Technical Reference Guide
If a power failure occurs, configurations which require loop power only
continue to work if the Meridian 1 Option 11C Compact is equipped with a
backup commercial power source such as an Uninterruptible Power Supply
(UPS). Only those options which require additional power will cease to
function.
During a power failure, the carbon agent headset on the M2216ACD-2 will
fail and the electret supervisor's jack can be used as an agent jack. If no
headset was plugged in to the electret jack at this time, the call is dropped, the
agent logged off and must log in again once the electret headset is plugged in.
When power is restored, the carbon jack returns automatically.
Table 28
Power requirements
Power Supply Board
The power supply option consists of a Power Supply Board which mounts
inside the telephone, coupled with an external wall-mount transformer or
closet power supply which provides power to the Power Supply Board. The
Power Supply Board receives its power through pins 1 and 6 of the line cord.
The Power Supply Board connects to the telephone through a 14 pin bottom
entry connector.
Telephone type
Loop power
Additional power
(Power Supply Board)
M2006
Basic configuration
Any option
M2008
Basic configuration
Any option
M2016S
No
All configurations
M2616
Basic configuration (with
Handsfree) and Display
Programmable Data Adapter
Key Expansion Module
External alerter interface
M2216ACD-1
Basic configuration (with Display)
Any option
M2216ACD-2
No
All configurations
Summary of Contents for Meridian 1 Option 11C Compact
Page 3: ...553 3121 100 Standard 2 0 September 1998 ...
Page 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Page 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Page 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Page 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Page 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Page 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...