Page 120 of 136
Chapter 12 — NTMW44 Universal Trunk Card
553-3121-100
Standard 2.0
September 1998
Environmental specifications
Table 47 lists the environmental specifications for the Universal Trunk Card.
Table 47
Environmental specifications
Foreign and surge voltage protection
The Universal Trunk Card meets CS03 overvoltage (power cross)
specifications.
Release control
Release control establishes which end of a call (near, far, either, joint, or
originating) disconnects the call. Only incoming trunks in idle ground start
configuration can provide disconnect supervision. You configure release
control for each trunk independently in the Route Data Block (LD 16).
PAD switching
The transmission properties of each trunk are characterized by the
class-of-service (COS) assigned in the Trunk Data Block (LD 14).
Transmission properties may be via net loss (VNL) or non via net loss
(non-VNL).
+ 8.5 V DC
± 2%
120 ma
120 ma
- 48.0 V DC
± 5%
346 ma
346 ma
+ 5.0 V DC
± 10%
350 ma
350 ma
Parameter
Specifications
Operating temperature
0 to 50 degrees C, ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
- 40 to + 70 degrees C
Summary of Contents for Meridian 1 Option 11C Compact
Page 3: ...553 3121 100 Standard 2 0 September 1998 ...
Page 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Page 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Page 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Page 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Page 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Page 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...