Chapter 11 — NTMW07 Trunk/Line Card
Page 109 of 136
Meridian 1 Option 11C Compact
Technical Reference Guide
— When the NTMW07 card is in slot 15 & 16
TN 15 03 connects to TN 16 03
(Trunk on Card 15 Unit 03 connects to the telephone on Card 16
Unit 03)
Power requirements
Power requirements for the NTMW07 Trunk/Line Card are shown in
Table 40.
Table 40
Power requirements
Environmental specifications
Table 41 lists the environmental specifications for the Universal Trunk Card.
Table 41
Environmental specifications
Foreign and surge voltage protection
The Universal Trunk Card meets CS03 overvoltage (power cross)
specifications.
Release control
Release control establishes which end of a call (near, far, either, joint, or
originating) disconnects the call. Only incoming trunks in idle ground start
configuration can provide disconnect supervision. You configure release
control for each trunk independently in the Route Data Block (LD 16).
Voltage
Tolerance
Idle current
Active current
± 15.0 V DC
± 5%
306 ma
306 ma
+ 8.5 V DC
± 2%
120 ma
120 ma
- 48.0 V DC
± 5%
346 ma
346 ma
+ 5.0 V DC
± 10%
350 ma
350 ma
Parameter
Specifications
Operating temperature
0 to 50 degrees C, ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
- 40 to + 70 degrees C
Summary of Contents for Meridian 1 Option 11C Compact
Page 3: ...553 3121 100 Standard 2 0 September 1998 ...
Page 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Page 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Page 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Page 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Page 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Page 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...