Frequency Response
Frequency Response (Attenuation Distortion) at a given frequency is the
difference between the loss at the test frequency and the loss at the reference
frequency.
gives the frequency response for 2 wire interfaces.
Table 5
Frequency Response
•
The symbol (+) denotes a loss and the symbol (-) denotes a gain.
•
Reference Sources:
1024 Hz -10 dBmO
2 Wire Interface
Frequency (Hz)
Minimum
Maximum
200
0
5
300
-0.5
1.0
3000
-0.5
1
3200
-0.5
1.5
3400
0
3.0