Preparing the system
Page 93 of 120
Installation and Configuration
Note:
Packet data testing can be conducted only if an external packet
handler or an Meridian Packet Handler (MPH) is installed as part of the
customer configuration, and is supported by the system (like the external
DPN-100 packet handler). If packet handler is not part of the
configuration, do not equip the DSLs with packet data terminals and skip
all the packet data tests specified in this chapter.
3
Equip the UILC DSL with a network terminator (NT1) and connect the two
voice and one circuit-switched data ISDN BRI terminal to the S/T interface
on the NT1.
4
Configure the DSLs to support these ISDN BRI terminals and initialize the
terminals as described in the “Initialize ISDN BRI terminals” section of the
ISDN Basic Rate Interface: Features
(553-3001-380)
.
End of Procedure
After you have completed the setup to perform acceptance testing, proceed
with the tests described in “Testing ISDN BRI functions” on
.
Summary of Contents for Communication Server 1000M
Page 2: ......
Page 4: ...Page 4 of 120 Revision history 553 3001 218 Standard 2 00 September 2004...
Page 12: ...Page 12 of 120 About this document 553 3001 218 Standard 2 00 September 2004...
Page 16: ...Page 16 of 120 Preparing for installation 553 3001 218 Standard 2 00 September 2004...
Page 52: ...Page 52 of 120 Installing ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 90: ...Page 90 of 120 Configuring ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 98: ...Page 98 of 120 Preparing the system 553 3001 218 Standard 2 00 September 2004...
Page 120: ...Page 120 of 120 Generating traffic reports 553 3001 218 Standard 2 00 September 2004...
Page 121: ......