Testing ISDN BRI functions
Page 115 of 120
Installation and Configuration
Procedure 39
Perform a D-channel Switched Virtual Circuit packet data transmission
test using an MPH
1
From an ISDN BRI D-channel packet data terminal, dial another local
ISDN BRI packet data terminal or a remote packet data terminal
(depending on how you have configured your MPH application).
Establish an active call connection.
2
After the call-originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call-originating ISDN BRI terminal can begin transmitting packet data.
3
Verify that the transmitted data has been received successfully by
checking the transmitted information for accuracy. Read the information
on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the same MPH for
local transmission and between a system ISDN BRI terminal and a
remote ISDN BRI terminal over the Packet Switched Data Network
(PSDN).
5
Release the connection.
Summary of Contents for Communication Server 1000M
Page 2: ......
Page 4: ...Page 4 of 120 Revision history 553 3001 218 Standard 2 00 September 2004...
Page 12: ...Page 12 of 120 About this document 553 3001 218 Standard 2 00 September 2004...
Page 16: ...Page 16 of 120 Preparing for installation 553 3001 218 Standard 2 00 September 2004...
Page 52: ...Page 52 of 120 Installing ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 90: ...Page 90 of 120 Configuring ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 98: ...Page 98 of 120 Preparing the system 553 3001 218 Standard 2 00 September 2004...
Page 120: ...Page 120 of 120 Generating traffic reports 553 3001 218 Standard 2 00 September 2004...
Page 121: ......