Page 22 of 66 Agent Greeting Card Test and Debug Capabilities
NTPH13AA_maint 3.01 February 2006
In addition on Media Card Agent Greeting (NTVQ09BA), if the IXP1200
encounters any failures during it’s initialisation, a “H:XX” error code appears
on the hex display. The list of error codes are as follows:
Debug Terminal Access
The Agent Greeting Card Debug Terminal access is provided via an RS-232
port. This is accessible via the NTAG81CA faceplate serial cable. Messages
indicating the completion of each self test phase, as well as any detected faults
will be logged to this serial port.
The pinouts for the Mini-DIN Connector, to which the faceplate serial (aka
maintenance) cable connects, are given in Table 4 on page 22.
The terminal connected to the serial port requires these settings: 9600bps, 8
data bits, 1 stop bit, no parity, and no flow control.
Table 3: IXP12
00 Initialisation hex display error codes
Display Code
Description
H:00
IXP1200 not booting
H:01
SDRAM test failure
H:02
SRAM test failure
H:04
PCMCIA device failure
H:08
Network interface failure
H:10
Meridian interface failure
H:20
DSP interface failure
H:40
NVRAM/EEPROM interface failure
H:80
PCM connector failure
Table 4: Faceplate Mini-DIN Connector pinout
Pin No.
Signal
Dir
Description
1
BDTRB-
O
Port B Data Terminal Ready
Summary of Contents for Agent Greeting NTVQ09AB
Page 2: ...Page 8 of 66 NTPH13AA_maint 3 01 February 2006...
Page 4: ...Page 10 of 66 NTPH13AA_maint 3 01 February 2006...
Page 8: ...Page 14 of 66 List of tables NTPH13AA_maint version 3 01 Februrary 2006...
Page 36: ...Page 42 of 66 Agent Greeting Application Upgrades NTPH13AA_maint 3 01 February 2006...
Page 52: ...Page 58 of 66 Troubleshooting Agent Greeting NTPH13AA_maint 3 01 February 2006...
Page 59: ...Page 65 of 66 Agent Greeting Card Maintenance and Troubleshooting Guide 66...
Page 60: ...Page 66 of 66 Appendix A Fatal Error codes NTPH13AA_maint 3 01 February 2006...
Page 61: ......