Nortel 1750 Install Manual Download Page 1

Version 7.05.300

NN46110-316 02.01
318022-C Rev 01
November 2007
Standard

600 Technology Park Drive
Billerica, MA  01821-4130

Nortel VPN Router Installation 
— VPN Router 1750 

Summary of Contents for 1750

Page 1: ...Version 7 05 300 NN46110 316 02 01 318022 C Rev 01 November 2007 Standard 600 Technology Park Drive Billerica MA 01821 4130 Nortel VPN Router Installation VPN Router 1750 ...

Page 2: ...respective owners Statement of conditions In the interest of improving internal design operational function and or reliability Nortel Networks Inc reserves the right to make changes to the products described in this document without notice Nortel Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein USA require...

Page 3: ... to take appropriate measures Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de créer des interférences radioélectriques il appartien...

Page 4: ...components data audio visual content such as images text recordings or pictures and related licensed materials including all whole or partial copies Nortel Networks grants you a license to use the Software only in the country where you acquired the Software You obtain no rights other than those granted to you under this License Agreement You are responsible for the selection of the Software and fo...

Page 5: ... POSSIBILITY The forgoing limitations of remedies also apply to any developer and or supplier of the Software Such developer and or supplier is an intended beneficiary of this Section Some jurisdictions do not allow these limitations or exclusions and in such event they may not apply 4 General a If Customer is the United States Government the following paragraph shall apply All Nortel Networks Sof...

Page 6: ...6 NN46110 316 02 01 ...

Page 7: ...pecialist by using an Express Routing Code 18 Getting help through a Nortel distributor or reseller 19 Preface 21 Before you begin 21 Text conventions 22 Acronyms 22 Related publications 23 Printed technical manuals 24 Chapter 1 Cabling the VPN Router and turning the power on 25 Connecting communications cables 26 Connecting the power cord 28 Verifying a successful installation 29 Understanding th...

Page 8: ...scription of the Nortel VPN Router 1750 41 Preparing to install the Nortel VPN Router 1750 42 Shipment contents 43 Additional equipment 44 Cables 44 Hardware for mounting the chassis in an equipment rack 44 Site requirements 44 Installing the chassis 45 Installing the chassis on a flat surface 45 Installing the chassis in an equipment rack 46 Rack mount recommendations 46 Attaching the shelf in th...

Page 9: ...ifications 75 System ports 76 10 100BASE TX Ethernet LAN ports 76 Serial port 77 Modem cable specifications 78 Hardware option cards 79 VPN Router Security Accelerator card 80 SSL VPN Module 1000 81 10 100BASE TX Ethernet interface card 83 1000BASE T 1000 GT Ethernet interface card 83 1000BASE T 1000 MT Ethernet interface card 85 1000BASE SX Ethernet interface card 87 56 64K CSU DSU WAN interface ...

Page 10: ...10 Nortel VPN Router Installation VPN Router 1750 HSSI WAN interface card 100 Index 103 ...

Page 11: ...V 35 X 21 WAN interface card 39 Figure 13 LEDs on the SSL VPN Module 1000 40 Figure 14 Front view of the Nortel VPN Router 1750 42 Figure 15 Placement of rubber feet on the bottom of the chassis 45 Figure 16 Attaching the cage nuts to the rack 47 Figure 17 Installing the shelf in the equipment rack 47 Figure 18 Removing the front bezel 48 Figure 19 Replacing the front bezel 49 Figure 20 Removing t...

Page 12: ...re 35 1000BASE SX Ethernet interface card 87 Figure 36 56 64K CSU DSU WAN interface card 88 Figure 37 ADSL WAN interface card 90 Figure 38 ISDN BRI S T interface card or ISDN BRI U interface card 91 Figure 39 T1 E1 CSU DSU WAN interface card half height card 93 Figure 40 T1 E1 CSU DSU WAN interface card full height card 93 Figure 41 Quad T1 E1 CSU DSU WAN interface card 95 Figure 42 V 90 modem int...

Page 13: ...icators on the quad T1 E1 CSU DSU WAN interface card 38 Table 13 LED indicators on the single V 35 X 21 WAN interface card 39 Table 14 LED indicators on the SSL VPN Module 1000 40 Table 15 Items shipped with the Nortel VPN Router 1750 43 Table 16 Supported option cards for the Nortel VPN Router 1750 1750 58 Table 17 Physical electrical and environmental specifications 75 Table 18 10 100BASE TX Eth...

Page 14: ...110 316 02 01 Table 30 T1 E1 CSU DSU cable pinouts for straight through connection 95 Table 31 MV 90 modem cable pinouts 96 Table 32 V 35 cable pinouts 97 Table 33 X 21 cable pinouts 99 Table 34 T3 cable pinouts 100 ...

Page 15: ... Router 1750 NN46110 316 for Release 7 05 300 Features See the following section for information about feature changes 1000BASE T 1000 GT Ethernet card The 1000BASE T 1000 GT Ethernet card replaces the 10 100BASE TX Ethernet card See 1000BASE T 1000 GT Ethernet interface card LEDs on page 32 and 1000BASE T 1000 GT Ethernet interface card on page 83 ...

Page 16: ...16 New in this release NN46110 316 02 01 ...

Page 17: ...time the product was released To check for updates to the latest documentation and software for VPN Router 1750 go to www nortel com support Select Security VPN and then in the section called Virtual Private Networking VPN IPSEC and SSL click the appropriate VPN Router product Getting help from the Nortel Web site The best way to get technical support for Nortel products is from the Nortel Technic...

Page 18: ... a Nortel Solutions Center If you do not find the information you require on the Nortel Technical Support Web site and you have a Nortel support contract you can also get help over the phone from a Nortel Solutions Center In North America call 1 800 4NORTEL 1 800 466 7835 Outside North America go to the following Web site to obtain the phone number for your region www nortel com callus Getting hel...

Page 19: ...ation VPN Router 1750 Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller ...

Page 20: ...20 How to get help NN46110 316 02 01 ...

Page 21: ...N Router 1750 For complete information about configuring and monitoring the VPN Router 1750 see the documentation on the software CD For information about VPN Router documentation see Related publications on page 23 Before you begin This guide is intended for qualified service personnel who are installing the VPN Router 1750 for the first time or who need to install or replace any of the following...

Page 22: ... titles plain Courier text Indicates system output for example prompts and system messages Example File not found separator Shows menu paths Example Choose Status Health Check ADSL asymmetric digital subscriber line AES Advanced Encryption Standard AIS alarm indication signal CSU DSU channel service unit digital service unit DES Data Encryption Standard DIMM dual inline memory module DTE data term...

Page 23: ...tel VPN Router Security Servers Authentication and Certificates NN46110 600 provides instructions for configuring authentication servers and services as well as digital certificates Nortel VPN Router Security Firewalls Filters NAT and QoS NN46110 601 provides instructions for configuring the VPN Router Stateful Firewall NAT and VPN Router interface and tunnel filters Nortel VPN Router Configuratio...

Page 24: ...des syntax descriptions and examples for the commands that you can use to configure manage and monitor the gateway Nortel VPN Router Troubleshooting NN46110 602 provides information about backup and recovery file management upgrading software and troubleshooting This guide also provides instructions for monitoring gateway status and performance Nortel VPN Router Configuration TunnelGuard NN46110 3...

Page 25: ...ics Caution Connect the cables to the built in Ethernet ports and to the interfaces on the option cards installed in the VPN Router 1750 before you plug the power cord into the outlet Topic Page Connecting communications cables 26 Connecting the power cord 28 Verifying a successful installation 29 Understanding the LEDs 30 Caution You must route the cabling for all wide area network WAN local area...

Page 26: ...ts see Appendix A Technical specifications on page 75 Table 1 Interfaces and cables for the Nortel VPN Router 1750 Cable available from Nortel Interface Included Ordered separately Contact supplier 10 100BASE TX Ethernet system ports X Serial port X 10 100BASE TX Ethernet X 1000BASE T 1000 GT Ethernet X 1000BASE T 1000 MT Ethernet copper X 1000BASE SX Ethernet fiber X1 1 Order either the LC to LC ...

Page 27: ...E TX RJ 45 cables to the built in 10 100BASE TX Ethernet LAN ports on the gateway Figure 1 2 If you plan to connect a terminal or PC to the gateway connect the serial cable that is shipped with the VPN Router 1750 to the serial port Figure 1 3 Connect all other cables to the ports on the installed interface cards If you ordered optional interface cards connect the cables for these interfaces to th...

Page 28: ...power outlet Table 2 Power cord requirements Requirement Description Current rating The power cord must be rated for the available AC voltage and must have a current rating that is at least 125 percent of the gateway s current rating 5 A 100 VAC or 3 A 240 VAC Certification The power cord must have certification marks from an acceptable regional agency Cord length and flexibility The power cord mu...

Page 29: ...rt LED turns off 4 After the boot process is complete the Boot Ready LED lights green indicating that the gateway is operational 5 The Alert LED lights yellow because the gateway is not configured For a newly installed VPN Router 1750 a yellow Alert LED does not indicate an alarm condition After you configure the gateway the Alert LED turns off See Chapter 4 Configuring the management IP interface...

Page 30: ... For complete information about the health check event log and system log see Nortel VPN Router Troubleshooting Table 3 Front panel LED indicators LED Indicator Description Power Nortel logo On The gateway is receiving AC power Off The gateway is not receiving AC power Alert Yellow A non fatal alarm condition exists The yellow alert condition is described in the health check display Red A serious ...

Page 31: ...scribes the LEDs on the system 10 100BASE TX Ethernet ports Table 4 LED indicators on the system 10 100BASE TX Ethernet ports LED Indicator Description Green On The LAN port is operating at 100 Mb s Off The LAN port is operating at 10 Mb s Yellow On The cable connections between the LAN port and the hub are good Off The cable connections between the LAN port and the hub are faulty Flashing The LAN...

Page 32: ...following figure shows the LEDs on the 1000BASE T 1000 GT Ethernet interface card Figure 5 LEDs on the 1000BASE T 1000 GT Ethernet interface card Table 5 LED indicators on the 10 100BASE TX Ethernet interface card LED Indicator Description ACT LINK Steady green or Flashing green The card is sending or receiving network data The frequency of the flashes increases with increased traffic Off The card...

Page 33: ...cator Description ACT LINK Steady green The port is connected to a valid link partner Flashing green The card is sending or receiving network data The frequency of the flashes increases with increased traffic Off The card is not sending or receiving data 10 100 1000 Yellow The port is operating at 1000 Mb s Green The port is operating at 100 Mb s Off The port is operating at 10 Mb s Table 7 LED in...

Page 34: ...he LAN port is operating at 10 Mb s Green The LAN port is operating at 100 Mb s Orange The LAN port is operating at 1000 Mb s Table 8 LED indicator on the 1000BASE SX Ethernet interface card LED Indicator Description ACT LNK Steady green The port is connected to a valid link partner Flashing green The LAN port is sending or receiving network data Off The port is not linked to a valid partner Table...

Page 35: ...when the interface card detects a DDS out of frame OOF condition on the receive signal Red The red alarm LED is lit when the interface card detects a DDS loss of signal LOS or loss of frame LOF condition on the receive signal Yellow The yellow alarm LED is lit when the interface card detects a DDS out of service condition on the receive signal This LED indicates that the far end equipment detects ...

Page 36: ...N LED Tx Rx LED Description Steady green Steady green The ADSL interface card is not initialized the software driver is not installed Off Off The ADSL interface card is initialized but has not established a link with the ADSL network Flashing green Off The ADSL interface card is attempting to establish a link with the ADSL network Steady green Off The ADSL interface card has established a link wit...

Page 37: ...LED indicators on the T1 E1 CSU DSU WAN interface card LED Indicator Description LED 1 Red The red alarm LED is lit when a loss of signal LOS or out of frame OOF condition is detected on the receive signal LED 2 Blue The blue alarm LED is lit when receiving an upstream failure denoted by an alarm indication signal AIS LED 3 Yellow The yellow alarm LED is lit when the far end equipment is in the re...

Page 38: ...e card LED Indicator Description LED 1 Off Port 1 is disabled On Port 1 is enabled and operating normally Flashing Port 1 is enabled and in an alarm state red yellow or blue LED 2 Off Port 2 is disabled On Port 2 is enabled and operating normally Flashing Port 2 is enabled and in an alarm state red yellow or blue LED 3 Off Port 3 is disabled On Port 3 is enabled and operating normally Flashing Por...

Page 39: ...ble 13 describes the LEDs on the single V 35 X 21 WAN interface card Table 13 LED indicators on the single V 35 X 21 WAN interface card LED Indicator Description LED 1 Red No external transmit clock source is available LED 2 Green The signals CDC and DSR are on between the DSU and the adapter LED 2 detects receive link status LED 3 Green Power to the adapter is on and the onboard microcode is load...

Page 40: ...e SSL VPN Module 1000 Off The SSL VPN Module 1000 is not receiving power Activity LED 1 Steady green The SSL VPN Module 1000 is operating normally Flashing green Activity is occurring on the SSL VPN Module 1000 Yellow A reset occurred on the SSL VPN Module 1000 Activity LED 2 Not used This LED is often lit but it has no meaning Utilization 4 LEDs Steady green Together these four LEDs indicate an a...

Page 41: ...ata network The VPN Router 1750 provides routing firewall bandwidth management encryption authentication and data integrity services to ensure secure tunneling across IP networks and the Internet The VPN Router 1750 is available in four models VPN Router 1750 with 5 tunnels 56 bit or 128 bit VPN Router 1750 with 500 tunnels 56 bit or 128 bit Note Before you install the chassis use standard cable s...

Page 42: ...s that can contain interface cards a VPN Accelerator card VPN Router Security Accelerator CSA card or Hardware Accelerator card and the Secure Sockets Layer SSL VPN Module 1000 a memory of 128 MB that is upgradable to 256 MB total Preparing to install the Nortel VPN Router 1750 Before you begin the installation verify that Your shipment is complete and undamaged You have the cables tools and other...

Page 43: ...4 10 32 panhead screws Secures the rack mount shelf and the chassis to the equipment rack 4 10 32 panhead cage nuts Used if the equipment rack does not have threaded rail holes 4 Rubber feet Used to install the chassis on a surface 1 Antistatic wrist strap Directs the discharge of static electricity from your body to the chassis to prevent damage to sensitive electronic components 1 Molded serial ...

Page 44: ...strator Hardware for mounting the chassis in an equipment rack To install the VPN Router 1750 in an equipment rack you need a Phillips screwdriver and an equipment rack that meets the following specifications heavy duty steel construction width of 19 in 48 26 cm and depth of 24 in 60 96 cm Electronic Industries Association EIA standard hole spacing If the rack does not have threaded rail holes you...

Page 45: ...ack on page 46 Installing the chassis on a flat surface If you decide to place the VPN Router 1750 on a flat surface make sure that the surface is large enough for the gateway and sturdy enough to support the combined weight of the VPN Router 1750 and the cables that you attach to it The VPN Router 1750 accessory kit includes four rubber feet that can be attached to the bottom of the gateway Figur...

Page 46: ... not exceed 40oC 104oF Do not block the power supply vents or otherwise restrict air flow when installing the chassis in the rack Stabilize your rack so that it does not tip over under the weight of the gateway and other devices Ensure that the electrical branch circuits can handle the VPN Router 1750 and other units in the rack before you install and turn on the gateway Maintain a reliable earth ...

Page 47: ...he shelf with holes in the front of the rack Figure 17 Installing the shelf in the equipment rack 4 Snap the support flange into place Figure 17 Ensure that the alignment pin above the flange fits into the appropriate hole 5 Insert one of the supplied panhead screws through the top hole on each side of the shelf into the hole in the rack and tighten the screws Figure 17 CS260003A Cage nut Rail wit...

Page 48: ...ezel from the VPN Router 1750 Figure 18 a Use the Phillips screwdriver to turn each of the two screws on the front bezel a quarter turn counterclockwise Figure 18 Removing the front bezel b Grip the two handles and firmly pull the bezel toward you to unsnap it from the chassis The first several times that you remove the front bezel the bezel can stick because the ball studs and socket clips are ne...

Page 49: ...e bottom hole on each side of the shelf into the hole in the rack and tighten the screws Figure 17 on page 47 4 Replace the front bezel Figure 19 a Hold the two handles on the bezel and push it onto the chassis b Use the Phillips screwdriver to tighten the two screws that secure the bezel to the chassis Figure 19 Replacing the front bezel CS260005E Press here ...

Page 50: ...50 Chapter 2 Installing the Nortel VPN Router 1750 chassis NN46110 316 02 01 ...

Page 51: ...interface cards Secure Sockets Layer SSL VPN Module 1000 VPN Accelerator cards VPN Router Security Accelerator CSA card and Hardware Accelerator card dual inline memory modules DIMM This chapter contains the following topics Topic Page Shutting down the system to add or replace hardware 52 Removing the front bezel and top cover 53 Attaching the antistatic wrist strap 57 Installing and replacing op...

Page 52: ...mple enter reload power off disable logins Upgrade hardware For the complete syntax of the reload command see Nortel VPN Router Using the Command Line Interface NN46110 507 2 Wait for the system to shut down 3 Disconnect the power cord from the power outlet and then disconnect the cord from the VPN Router 1750 The power receptacle is on the rear of the VPN Router 1750 see Figure 1 on page 27 Warni...

Page 53: ...Shut down the VPN Router 1750 using the Web GUI or the CLI and then unplug it as described in Shutting down the system to add or replace hardware on page 52 2 Use a Phillips screwdriver to turn each of the two screws on the front bezel a quarter turn counterclockwise Figure 20 Figure 20 Removing the front bezel Warning Risk of electric shock Make sure to turn off the VPN Router 1750 and unplug it ...

Page 54: ...op cover 1 Remove the router from the rack if it is mounted in an equipment rack a At the front of the chassis remove the two panhead screws that secure the bottom of the chassis to the equipment rack b Remove the VPN Router 1750 from the rack mount shelf and set the router on a sturdy surface 2 Use a Phillips screwdriver to remove the four screws that secure the cover to the chassis Figure 21 Cau...

Page 55: ...DIMMs 55 Nortel VPN Router Installation VPN Router 1750 Figure 21 Removing the top cover 3 Slide the top cover forward approximately 1 4 inch CS260006A Remove these 4 screws Slide cover forward and lift up Boot Ready Alert Alert Boot Ready ...

Page 56: ...tion card and DIMM slots on the system board Warning Risk of injury Beware of danger if you incorrectly replace the battery Replace the battery with the same type or an equivalent battery only as recommended by the manufacturer s instructions In spite of this warning which is mandated for regulatory approval you must not change the battery If you suspect a dead battery contact Nortel Customer Supp...

Page 57: ...IMMs To attach the antistatic wrist strap 1 Locate the antistatic wrist strap and verify that the cable is attached to the wrist strap 2 Place the strap around your wrist and adjust the strap to ensure that the metal buckle inside the strap touches your skin 3 Insert the banana plug into the grounding jack at the rear of the chassis Figure 23 Figure 23 Location of the grounding jack for the antist...

Page 58: ...ll a Hardware Accelerator card in slot 4 Hardware Accelerator 10 100BASE TX Ethernet interface 4 1000BASE T 1000 GT Ethernet interface3 4 1000BASE T 1000 MT interface copper 4 2 Install two 1000BASE T 1000 MT cards two 1000BASE SX cards or one card of each type But see Installing the SSL VPN Module 1000 with other option cards on page 59 1000BASE SX interface fiber 5 56 64K channel service unit di...

Page 59: ...stall in slot 4 install in slot 3 or 1 if possible If an SSL VPN Module 1000 is installed you can install only one HSSI WAN interface card 1 The VPN Router 1750 must be running Version 5 0 or later 2 The VPN Router 1750 must be running Version 4 90 or later 3 The VPN Router 1750 must be running Version 5 05 330 6 05 140 and later 7 00 062 7 05 100 and later or 7 05 300 and later 4 The VPN Router 1...

Page 60: ...op cover on page 53 3 Remove the top cover from the chassis see Removing the front bezel and top cover on page 53 4 Attach the antistatic wrist strap that was shipped with the VPN Router 1750 see Attaching the antistatic wrist strap on page 57 5 Locate the slot where you plan to install the new or replacement option card 6 Remove the filler panel screw and pull out the filler panel or the option c...

Page 61: ...Replace the screw that secures the card to the slot Figure 24 on page 61 9 Replace the top cover on the chassis Figure 21 on page 55 a Hold the cover at an angle and slide it onto the chassis b Use a screwdriver to insert and tighten the four screws that secure the cover to the chassis 10 If the VPN Router 1750 is installed in an equipment rack mount it in the rack a Set the VPN Router 1750 on the...

Page 62: ... screwdriver to tighten the two screws that secure the bezel to the chassis Figure 25 Replacing the front bezel Installing and replacing DIMMs The VPN Router 1750 has two slots for dual inline memory modules DIMM Figure 22 on page 56 Unless you ordered additional memory the VPN Router 1750 is shipped with one 128 MB DIMM installed You can upgrade memory in the gateway by installing a second 128 MB...

Page 63: ...e the chassis from the equipment rack see Removing the front bezel and top cover on page 53 3 Remove the top cover from the chassis see Removing the front bezel and top cover on page 53 4 Attach the antistatic wrist strap that was shipped with the VPN Router 1750 see Attaching the antistatic wrist strap on page 57 Caution Install the same type of DIMM that is already installed in your gateway For ...

Page 64: ...he slot where you plan to install the new DIMM Figure 26 7 Place the new or replacement DIMM in the slot Figure 26 Use the alignment keys to properly position the DIMM in the slot 8 Press the DIMM firmly into the socket 9 Pull up the locking lever on either side of the DIMM to snap it into position Figure 26 Installing and removing a DIMM To remove DIMMs pull back locking levers and pull out DIMM ...

Page 65: ...he screws 11 If the VPN Router 1750 is installed in an equipment rack mount it in the rack a Set the VPN Router 1750 on the rack mount shelf in the rack b Insert one of the panhead screws through the bottom hole on each side of the shelf into the hole in the rack and tighten the screws Figure 17 on page 47 12 Replace the front bezel Figure 25 on page 62 a Hold the bezel by the two handles and push...

Page 66: ...66 Chapter 3 Installing option cards and DIMMs NN46110 316 02 01 ...

Page 67: ...After you complete the procedures in this chapter you can configure and manage the VPN Router 1750 using a Web browser from a PC To configure the management IP interface you use the serial interface configuration menu You must connect a PC or terminal to the serial port on the VPN Router 1750 This chapter contains the following topics Topic Page Required information 68 Configuring the management I...

Page 68: ...st reside in the 10 2 network Subnet mask The subnet mask specifies which IP addresses are directly reachable on the network and which ones must be routed through a gateway For example the IP address 10 2 3 3 with a subnet mask of 255 255 0 0 indicates that all hosts with addresses 10 2 n n are directly reachable Default gateway optional The default gateway routes packets to destinations for which...

Page 69: ...erial cable supplied with the VPN Router 1750 from the gateway s serial port to a terminal or to the communications port on a PC 3 On the PC start HyperTerminal or another terminal emulation program and press Enter The Nortel VPN Router window appears Nortel VPN Router Copyright c 1999 2005 Nortel Networks Inc Version V07_0 024 Creation date Jul 6 2006 08 23 16 Unit Serial Number 510649 Please ent...

Page 70: ...9 Shutdown B System Boot Options P Configure Serial Port C Controlled Crash L Command Line Interface R Reset System to Factory Defaults E Exit Save and Invoke Changes Please select a menu choice 0 9 B P C L R E 5 To configure the Interface IP address from the serial menu type 1 and press Enter The interface menu appears Interface Menu 0 Slot 0 Port 2 Public LAN IP Address Subnet Mask 0 0 0 0 Speed...

Page 71: ... Enter The subnet mask prompt appears Old Subnet Mask 0 0 0 0 New Subnet Mask 8 At the New Subnet Mask prompt type the subnet mask for the management IP address and press Enter The Speed Duplex prompt appears 9 Press Enter to leave the speed and duplex settings unchanged The Interface menu appears again with the changes you made 0 Slot 0 Port 2 Public LAN IP Address Subnet Mask 0 0 0 0 Speed Duple...

Page 72: ... New management IP address 12 Type the new management IP address and press Enter to configure the management IP address The new IP management address appears in the Management IP Address menu Management IP address menu M Management IP Address 192 167 120 13 R Return to the Main Menu Please select a menu choice M R 13 Type R and press Enter to return to the serial main menu The serial main menu app...

Page 73: ...e running one of the following browsers Internet Explorer Version 5 5 or later Netscape Navigator 4 79 or 6 2 To test the management IP address on the VPN Router 1750 1 Open a Web browser 2 In the URL field enter http followed by the management IP address that you assigned to the VPN Router 1750 For example if the management IP address is 47 17 248 52 enter http 47 17 248 52 If the Welcome window ...

Page 74: ...ay Ensure that your PC is running a supported browser either Internet Explorer Version 5 5 or later or Netscape Navigator 4 79 or 6 2 Check the physical connections on the VPN Router 1750 especially the LAN cables and the power cord If you still cannot connect to the VPN Router 1750 using a browser connect a terminal or PC to the gateway with the serial cable and check the management IP address li...

Page 75: ...l specifications for the chassis Table 17 Physical electrical and environmental specifications Specification Description Physical Height 5 25 in 13 335 cm Width 17 in 43 18 cm Depth 21 in 53 34 cm Weight 28 lbs 12 7 kg Electrical Voltage 100 240 VAC Current 5 A 100 VAC or 3 A 240 VAC Frequency 50 60 Hz Environmental Operating temperature 32 104oF 0 40oC Storage temperature 40 185oF 40 85oC Operati...

Page 76: ...or 10BASE T or 100BASE TX operation select cables for the interfaces as follows 100BASE TX connections require Category 5 twisted pair wire The 100BASE TX specification supports 100 Mb s transmission over two pairs of Category 5 twisted pair Ethernet wiring one pair each for transmit and receive operations Nortel recommends a maximum length of 100 meters for the cable segment between a 100BASE TX ...

Page 77: ...ent IP address and subnet mask to the newly installed gateway for more information see Chapter 4 Configuring the management IP interface on page 67 The serial cable provided with the VPN Router 1750 is a DB9 DB25 to DB9 DB25 cable This cable provides a crossover connection transmit to receive and receive to transmit The DB9 connector goes into the gateway and the other DB9 or DB25 connector goes i...

Page 78: ...S 232 C modem port Figure 29 Table 19 Multiple DB9 and DB25 connector pinouts Serial port DB9 connector Serial port DB25 connector Serial port DB25 connector Serial port DB9 connector Pinout Signal Pinout Signal Pinout Signal Pinout Signal 2 RXD 3 TXD 2 RXD 3 TXD 3 TXD 2 RXD 3 TXD 2 RXD 4 DTR 20 DSR 6 DTR 6 DSR 5 Ground 7 Ground 7 Ground 5 Ground 6 DSR 6 DTR 20 DSR 4 DTR 7 RTS 4 RTS 5 CTS 8 CTS 8 ...

Page 79: ... 10 100BASE TX Ethernet interface card Table 20 Modem cable pinouts Nortel termination Modem termination Signal Pin to Pin Signal Data Carrier Detect 1 8 Data Carrier Detect Transmit Data TXD 2 2 Transmit Data TXD Receive Data RXD 3 3 Receive Data RXD Data Set Ready 4 6 Data Set Ready Data Terminal Ready 6 20 Data Terminal Ready Clear to Send 7 5 Clear to Send Request to Send 8 4 Request to Send P...

Page 80: ...on about the option cards including the connector and the cable pinouts for each supported network interface card VPN Router Security Accelerator card Nortel supports the VPN Router Security Accelerator option card that performs bulk encryption and compression algorithms for IPsec tunnel traffic The VPN Router Security Accelerator card uses a single Hifn 7854 chip for encryption and compression an...

Page 81: ...elf test POST verifies the integrity of the hardware This test includes validation of the accelerator s encryption media access control MAC and compression algorithms against their software counterparts In the event POST fails the accelerator card is set offline For more information about the VPN Router Security Accelerator card and the Hardware Accelerator card and instructions for configuring th...

Page 82: ...N Router Version 5 0 software You must install the SSL VPN Module 1000 in slot 1 of the VPN Router 5000 2700 or 1750 The VPN Router gateway distinguishes between the services that it provides and the services that the SSL VPN Module 1000 provides and immediately forwards the appropriate traffic to the SSL VPN module Note For complete information about the SSL VPN Module 1000 and instructions for c...

Page 83: ...thernet card replaces the 10 100BASE TX Ethernet card see the previous section This card provides 10 100 1000 Mbit s Ethernet services and supports autonegotiation The card supports the IEEE 802 3ab standard and provides RJ 45 CAT 5 interconnection It can operate in either full or half duplex mode at 10 100 Mbit s and in full duplex mode at 1 Gbit s At 1 Gbit s autonegotiation must be used For the...

Page 84: ... the TIA 568 wiring specification Nortel recommends a maximum length of 100 meters for the cable segment For 100BASE TX operation use Category 5 twisted pair wiring one pair each for transmit and receive operations The cable must comply with the EIA 568 wiring specification Nortel recommends a maximum length of 100 meters for the cable segment For 10BASE T operation use Category 3 4 or 5 twisted p...

Page 85: ...ables for this port as follows For 1000BASE T operation use Category 5 four pair Ethernet wiring The cable must comply with the TIA 568 wiring specification Nortel recommends a maximum length of 100 meters for the cable segment For 100BASE TX operation use Category 5 twisted pair wiring one pair each for transmit and receive operations The cable must comply with the EIA 568 wiring specification No...

Page 86: ...86 Appendix A Technical specifications NN46110 316 02 01 7 TP3 8 TP3 Table 22 1000BASE T 1000 MT Ethernet port pinouts Pin Description ...

Page 87: ...has a single type LC fiber connector Figure 35 shows the 1000BASE SX Ethernet interface card Figure 35 1000BASE SX Ethernet interface card The port on the 1000BASE SX Ethernet interface card accommodates a multimode fiber MMF cable that meets MMF standards Select fiber cable for this interface as follows 50 micron MMF cable provides a distance range of 500 550 meters m 62 5 micron MMF cable provid...

Page 88: ... 48 modular patch cord Use cable that is wired in accordance with ANSI T1 410 wiring style This wiring style ensures that a twisted pair inside the patch cord carries the transmit signal pins 1 and 2 and the receive signal pins 7 and 8 Nortel strongly recommends that you use professionally manufactured patch cords You connect the 56 64K CSU DSU WAN interface card to the service provider network us...

Page 89: ...ion Remote termination Signal Pin to Pin Signal Transmit tip 1 7 Receive tip Transmit ring 2 8 Receive ring not used 3 3 not used not used 4 4 not used not used 5 5 not used not used 6 6 not used Receive tip 7 1 Transmit tip Receive ring 8 2 Transmit ring Table 24 56 64K CSU DSU cable pinouts for straight through connection Nortel termination Remote termination Signal Pin to Pin Signal Transmit ti...

Page 90: ...the ADSL WAN interface card Figure 37 ADSL WAN interface card Included in the accessory box with the ADSL WAN interface card is a 7 foot cable to attach to the DSLAM The Annex A cable is an RJ 11 to RJ 11 cable The Annex B cable is an RJ 11 to RJ 45 cable Table 25 provides the pinouts for the ADSL Annex A cable Note The ADSL Annex A and ADSL Annex B cards look identical Table 25 ADSL Annex A cable...

Page 91: ...device to the RJ 45 connector Figure 38 shows the ISDN BRI S T interface card or the ISDN BRI U interface card The two cards look identical Figure 38 ISDN BRI S T interface card or ISDN BRI U interface card The connector on the ISDN BRI S T and ISDN BRI U interface cards accommodates an 8 pin RJ 45 modular patch cord These cables are sold as Category 5 or Ethernet cables Table 26 ADSL Annex B cabl...

Page 92: ...28 provides the ISDN BRI U cable pinouts Table 27 ISDN BRI S T cable pinouts Pin Function 1 N C 2 N C 3 Receive 4 Transmit 5 Transmit 6 Receive 7 N C 8 N C Table 28 ISDN BRI U cable pinouts Pin Function 1 N C 2 N C 3 N C 4 U interface network connection tip 5 U interface network connection ring 6 N C 7 N C 8 N C ...

Page 93: ...ard Figure 40 T1 E1 CSU DSU WAN interface card full height card The connector on the T1 E1 CSU DSU WAN interface accommodates an 8 pin RJ 48 modular patch cord These cables are commonly sold as Category 5 or Ethernet cables Use cable that is wired in accordance with EIA 568 A wiring style This wiring style ensures that a twisted pair inside the patch cord carries the transmit signal pins 4 and 5 a...

Page 94: ...ble Table 29 provides the T1 E1 CSU DSU cable pinouts for a crossover connection The cable operates properly if you do not connect pins 3 6 7 and 8 Table 29 T1 E1 CSU DSU cable pinouts for crossover connection Standard wired end 8 pin male Signal name Pair number and conductor Special wired end 8 pin male 1 RXDA TXDA wht org pair 2A 5 2 RXDB TXDB orange pair 2B 4 3 not used wht grn pair 3A 3 4 TXD...

Page 95: ...terface card Each connector on the quad T1 E1 CSU DSU WAN interface card accommodates an 8 pin RJ 48 modular patch cord These cables are commonly sold as Category 5 or Ethernet cables Table 30 T1 E1 CSU DSU cable pinouts for straight through connection Nortel termination Remote termination Signal Pin to Pin Signal Receive A RXDA 1 1 Receive A RXDA Receive B RXDB 2 2 Receive B RXDB not used 3 3 not...

Page 96: ... cable For a crossover connection you cannot use a standard Category 5 crossover cable Do not interchange the T1 E1 CSU DSU crossover cable and the Ethernet crossover cable For information about the cable pinouts for a crossover connection see Table 29 on page 94 For information about the cable pinouts for a straight through connection see Table 30 on page 95 V 90 modem interface card The V 90 mod...

Page 97: ...ection and the gateway You can order a V 35 or X 21 cable to attach to the connector With this cable the WAN adapter can function as DTE data terminal equipment Table 32 provides the V 35 cable pinouts Table 33 on page 99 provides the X 21 cable pinouts The pair suffix A or B refers to an individual wire within a twisted pair 3 Ring 4 N C Table 32 V 35 cable pinouts Standard wired end 28 pin male ...

Page 98: ...te signals 17 RXCA pair 4A V 9 RXCB pair 4B X 24 SCTEA pair 5A U 11 SCTEB pair 5B W 4 RTSA pair 6A C 19 RTSB pair 6B no conn Note 1 5 CTSA pair 7A D 13 CTSB pair 7B no conn Note 1 6 DSRA pair 8A E 22 DSRB pair 8B J 20 DTRA pair 9A H 23 DTRB pair 9B no conn Note 1 8 DCDA pair 10A F 10 DCDB pair 10B no conn Note 1 18 LL pair 11A L 21 RL pair 11B N 25 TM pair 12A NN 26 M0 SIGNAL GROUND pair 12B B Not...

Page 99: ...15 TXCA pair 3A 6 12 TXCB pair 3B 13 17 RXCA pair 4A pair 5A Note 1 9 RXCB pair 4B pair 5B Note 1 24 SCTEA pair 5A pair 4A Note 1 11 SCTEB pair 5B pair 4B Note 1 4 RTSA pair 6A 3 19 RTSB pair 6B 10 5 CTSA pair 7A 5 13 CTSB pair 7B 12 6 DSRA pair 8A no conn Note 2 22 DSRB pair 8B no conn Note 2 20 DTRA pair 9A no conn Note 2 23 DTRB pair 9B no conn Note 2 8 DCDA pair 10A no conn Note 2 10 DCDB pair...

Page 100: ...interface card The HSSI WAN interface card has a 50 pin SCSI II female connector that provides the signals needed to interface to a T3 modem or modem eliminator Figure 44 shows the HSSI WAN interface card Figure 44 HSSI WAN interface card Included in the accessory box is a cable that maps the T3 signals out to a 50 pin SCSI II male connector Table 34 provides the T3 cable pinouts 1 SHIELD pair 14A...

Page 101: ... 9 10 LAB 10 11 TDB 11 12 LBB 12 13 GND 13 19 GND 19 24 TESTB 24 25 GND 25 26 GND 26 27 RCA 27 28 CAA 28 29 RDA 29 30 LCA 30 31 STA 31 32 GND 32 33 TAA 33 34 TTA 34 35 LAA 35 36 TDA 36 37 LBA 37 38 GND 38 44 GND 44 49 TESTA 49 50 GND 50 Table 34 T3 cable pinouts continued 50 pin SCSI male Signal name 50 pin SCSI male ...

Page 102: ...102 Appendix A Technical specifications NN46110 316 02 01 ...

Page 103: ...interface card cable specifications 85 connector 85 described 85 LEDs 33 1000BASE T Ethernet interface card installing 58 56 64K CSU DSU WAN interface card cable pinouts 89 91 connector 88 described 88 installing 58 LEDs 35 A AC power cord connecting 28 ordering 43 requirements 28 accelerator cards hardware encryption described 80 installing 58 accessories hardware shipped with the gateway 43 acro...

Page 104: ... to the gateway using a browser 73 connectors 10 100BASE system LAN port 76 10 100BASE TX Ethernet interface 83 1000BASE SX Ethernet interface 87 1000BASE T 1000 MT Ethernet interface 85 56 64K CSU DSU WAN interface 88 ADSL WAN interface 90 HSSI WAN interface 100 ISDN BRI S T interface 91 quad T1 E1 CSU DSU WAN interface 95 single V 35 X 21 WAN interface 97 T1 E1 CSU DSU WAN interface 93 V 90 mode...

Page 105: ...0 connector 100 installing 58 I installing DIMMs 62 installing option cards 58 installing the chassis in an equipment rack 46 on a flat surface 45 prerequisites 42 interfaces option card technical specifications 79 interfaces system technical specifications 76 Internet Explorer supported versions 73 IP address for managing the gateway See management IP address ISDN BRI S T interface card cable pin...

Page 106: ...d WAN interface cards P physical specifications 75 pinouts 10 100BASE Ethernet connector 76 1000BASE SX Ethernet interface 87 1000BASE T 1000 MT Ethernet interface 85 56 64K CSU DSU WAN interface 89 91 ADSL WAN interface Annex A 90 ADSL WAN interface Annex B 91 HSSI WAN interface 100 ISDN BRI S T interface 92 ISDN BRI U interface 92 modem cable 79 quad T1 E1 CSU DSU WAN interface 94 serial interfa...

Page 107: ... ports cable specifications 76 connector 76 LEDs 31 system ports specifications 76 T T1 E1 CSU DSU WAN interface card cable pinouts 94 connector 93 installing 58 LEDs 37 T3 HSSI WAN interface card See HSSI WAN interface card technical publications 24 technical specifications 75 testing connectivity to the gateway 73 text conventions 22 top cover removing 54 replacing 61 troubleshooting the managem...

Page 108: ...bed 80 installing 58 W WAN interface cards installing 58 LEDs 56 64K CSU DSU 35 ADSL 36 quad T1 E1 CSU DSU 38 single V 35 X 21 39 T1 E1 CSU DSU 37 specifications 56 64K CSU DSU 88 ADSL 90 HSSI 100 quad T1 E1 CSU DSU 95 single V 35 X 21 97 T1 E1 CSU DSU 93 Web interface to the gateway 73 wiring requirements Category 5 76 84 85 wrist strap antistatic attaching 57 X X 21 WAN interface card See single...

Reviews: