background image

25

Figure 11. Wiring Diagram for 208/230V / 3 Phase / 60 Hz Unit

208/230 

V

olt

Z

H0

6   

es

ah

eer

hT

re

noi

ti

dn

oC 

ri

A ci

rt

cel

E/t

ae

H s

a

eg

at

el

gni

de

ga

kc

aP

NO

TES:

1. Disconnec

t all power be

fo

re ser

vicing

.

2. F

or supply conec

tions use copper conduc

tors only

.

3. Not suitable on systems that ex

ceed  150v to ground

.

4. If an

y of the original wire as supplied with the furnace

    must be replaced, it must be replaced with wiring material

    having a temprature rating of at least 105C.

5. F

or supply wire ampacities and overcurrent protec

tion,

    see unit rating plat

e.

1. Couper le courant avant de faire letretien.

2. Employez uniquement des conduc

teurs en culvr

e.

9. Ne con

vient pas aux installations des plus de 150V

    a la terr

e.

TO THERMOS

TAT

FA

UL

CO

NDITIO

N

FA

UL

CO

NDITIO

NS

TA

TUS LIGHT (

YELL

OW

)

ST

ATUS LIGHT (RED

)

POWER ON

ON

ON

1 FLAS

H

2 FLAS

H

3 FLAS

H

4 FLAS

H

5 FLAS

H

CO

NTINUOUS FLAS

H

CO

NTINUOUS FLAS

H

OF

F

POWER OF

F

LO

W FLAME SENSOR SIGNAL

FLAME PRESEN

T

LIMIT CIRCUIT OPEN

IGNITION 

FA

IL

URE (CHECK GROUND

)

230 

VA

C & NEUTRAL REVERSED OR

NO GROUND

FA

LSE FLAME OR GAS RELA

Y

SHORTE

D

PRESURE SWIT

CH STUCK OPEN

WITH INDUCER ON

PRESURE SWIT

CH STUCK CL

OSED

WITH INDUCER OFF

WIRING DIA

GRAM

FIELD 

WIRIN

G

LEGEND

:

LO

VO

LT

AG

E

HIGH 

VO

LT

AG

E

10076210

05/15

FLAM

ES

TA

TU

S

L1

XF

MR

X13 

CO

M

HUM

 NEUTRALS

COM

3 AMP FUSE

BLOWER OF

F

24V

X13 

CO

OL

X13 HEA

T

X13 

FA

N



3



6



9



6



3

R

C

Y

G

W

R

C

1

2

2

1

2

-

1

8

7

6

5

4

3

2

9

1

8

7

6

5

4

3

2

9

TO

 208/230 

VA

C

POWER SUPP

LY

OUTDOOR 

FA

N

MO

TO

R

C

OMPRESSOR

C

ONT

AC

TO

R

C

OMPRESSOR

T2

T1

T3

CAP

A

CIT

OR

TO

 DISCHARGE

AIR SENSOR

BL

UE

YELLOW

YELLOW

PL

UG 

E

EC

ONOMIZER

AC

CESSORY PL

UG

EC

ONOMIZER JUMPER

HARNESS ASS

Y.

WIR

E

EC

ONOMIZER

ACC

ESSORY PL

UG

LO

W

PRESSURE

SWIT

CH

HIGH

PRESSURE

SWIT

CH

LIMIT

SWIT

CH

FLAME ROLL

-OUT

SWIT

CH

GROUND

FLAME

SENSOR

PRESSURE

SWIT

CH

GAS

VA

LV

E

2

1

 IGNIT

OR

 INDUCER

 N

 L

 C

 G

 TI

 T2

 T3

 T4

 T5

L1

L2

L3

  T3

  T2

  T1

BLACK

ORANGE

C

C

S

R

1

8

7

6

5

4

3

2

9

1

8

7

6

5

4

3

2

9

CC

H

 BLA

CK

 BLA

CK

BLACK

BLACK

BLACK

 24

V

208V

240V

 CO

M

G

C

W1

A1

Y2

Y1

R

 BLA

CK

 BL

UE

 BL

UE

 RED

 Y

ELL

OW

 BROWN

 RED

 GREEN/YELL

OW

 BLA

CK

 GREEN

 ORANGE

 BLUE

 ORANGE

 BLUE

 BL

UE

 BL

UE

 BLA

CK

 WHITE

 Y

ELL

OW

 ORANGE

 YELL

OW

 WHITE

RED

 BLA

CK

 YELL

OW

 ORANGE

 BROWN

 BROWN

 BLA

CK

 BLA

CK

RED

RED

RED

 BLA

CK

 WHITE

RED

RED

RED

 GREY

 GREEN

 Y

ELL

OW

 BL

UE

 Y

ELL

OW

 BLA

CK

 GREY

 GREEN

 Y

ELL

OW

 Y

ELL

OW

 BLA

CK

 RED

 WHITE

 GREEN

 WHITE

 WHITE

Wiring Diagrams

Summary of Contents for R8GE Series

Page 1: ...call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Nepasentreposerniutiliserdel essencenid autres vapeursouliquidesinflamma...

Page 2: ...P Propane Gas Conversion 15 START UP ADJUSTMENTS 16 Pre Start Check List 16 Start Up Procedure 16 Air Circulation 16 System Cooling 16 System Heating 16 Verifying Adjusting Temperature Rise 16 Verifyi...

Page 3: ...brancher S assurer de les raccorder correctement S assurer que l appareil fonctionne ad quatement apr s l entretien WARNING TheseunitsarefullychargedwithR 410Arefrigerant andreadyforinstallation When...

Page 4: ...d the air vent intake terminal See page 8 Combustionproductsmustbedischargedoutdoors Connect this unit to an approved vent system only as specified on page 8 Never test for gas leaks with an open flam...

Page 5: ...nt Clearance in accordance with local installation codes the requirements of the gas supplier and the manufacturer s installation instructions D gaugement conforme aux codes d installation locaux aux...

Page 6: ...s suivies pour chacun des appareils raccord s au syst me de ventilationaumomentdesamiseenmarche celapeut entra ner une intoxication au monoxyde de carbone ou la mort Les tapessuivantesdoivent tresuivi...

Page 7: ...als Carbon tetrachloride Halogen type refrigerants Cleaning solvents Cements glues paint removers varnishes etc Hydrochloric acid Masonry acid washing materials Plumbing Stack Venting Requirements Thi...

Page 8: ...ing operation If a combination of indoor and outdoor air is used the ducts and damper system must be designed so that the return air supply to the furnace is equal to the return air supply under norma...

Page 9: ...tbelocatedaccordingtolocalbuilding codes or ordinances and these requirements The roof must be capable of handling the weight of the unit For unit weights see Table 9 page 21 Reinforce the roof if nec...

Page 10: ...ove access panel screws from return air panel Hint Loosen the unit s top panel screws near the top edge of the access panel The access panel was designed to be captured underneath the top panel 2 Remo...

Page 11: ...iring methods must be acceptable to authority having jurisdiction Useonlycopperwireforthelinevoltagepowersupplytothis unit See Table 4 page 12 Use proper code agency listed conduit and a conduit conne...

Page 12: ...225 110 Table 5 Thermostat Wire Gauge Table 3 Electrical Data MODEL NUMBER HEATING INPUT BTUH NOMINAL ELECTRICAL SUPPLY VOLTAGE RANGE COMPRESSOR FAN AMPS BLOWER MOTOR AMPS MINIMUM CIRCUIT AMPACITY MAX...

Page 13: ...lating blower motor has started Set the heat anticipator according to the thermostat manufacturer s instructions for heat anticipator settings Blower Speed The blower speed is preset at the factory fo...

Page 14: ...tbrush If any bubbling is observed the connection is not sealed adequately and must be retightened Repeat the tightening and soap check process until bubbling ceases GAS SUPPLY PIPING WARNING FIRE OR...

Page 15: ...e carbon monoxide poisoning personal injury or death Conversion of this equipment to LP Propane gas must be made by qualified service personnel using approved factory parts Conversion to LP can be acc...

Page 16: ...andverifythecompressor fan and indoor blower energize 2 Feel the air being circulated by the indoor blower and verify that it is cooler than ambient temperature Listen for any unusual noises If unusua...

Page 17: ...operates for more thanfourminuteswithnoreturnair setthethermostatbelow room temperature shut off power to the unit and replace the over temperature limit control Verifying Burner Operation WARNING Un...

Page 18: ...ignition the furnace control is locked and the red LED will blink 4 times repetitively The thermostat must be opened for at least ten seconds to reset the furnace control after a lock out Otherwise t...

Page 19: ...e unit 4 Turn the gas control knob to the OFF position See Figure 10 page 24 for gas valve shut off instructions 5 Disconnect the wires from the gas valve ignitor and flame sensor CAUTION Use care whe...

Page 20: ...ustion blower will continue to operate if the flame roll out control opens Flame Sensor Proves that flame has carried over from the ignitor to the right most burner If no flame is sensed the unit will...

Page 21: ...al Supply Duct Opening Horizontal Return Duct Opening 4 0 1 75 9 75 24 75 16 0 Condensing Coil 13 5 16 0 16 0 C 13 5 Figure 9 R8GE Dimensions Table 9 Center of Gravity Unit Shipping Weights Model Numb...

Page 22: ...62 1113 66 T3 1788 41 1740 42 1692 44 1633 45 1574 47 1511 49 1449 51 1389 53 T4 1788 41 1740 42 1692 44 1633 45 1574 47 1511 49 1449 51 1389 53 T5 2015 37 1970 37 1915 39 1870 39 1805 41 1740 42 168...

Page 23: ...E REVOLUTION SECONDS CUBIC FEET PER REVOLUTION OF GAS METER 1 5 10 10 360 1 800 3 600 12 300 1 500 3 000 14 257 1 286 2 571 16 225 1 125 2 250 18 200 1 000 2 000 20 180 900 1 800 22 164 818 1 636 24 1...

Page 24: ...utili sant le t l phone d un voisin A d faut de la compagnie du gaz avertir le service des pompiers C Enfoncer ou faire tourner le robinet gaz la main seulement Nejamaisutiliserd outils S iln estpaspo...

Page 25: ...SE FLAME OR GAS RELAY SHORTED PRESURE SWITCH STUCK OPEN WITH INDUCER ON PRESURE SWITCH STUCK CLOSED WITH INDUCER OFF WIRING DIAGRAM FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE 10076210 05 15 FLAME ST...

Page 26: ...NGE BLUE RED GREEN YELLOW RED RED ORANGE WHITE WHITE BLUE YELLOW BLACK GREY GREEN BLACK BLACK GREEN WHITE YELLOW RED WHITE BLACK YELLOW 460 Volt Three Phase 60Hz 3 If any of the original wire as suppl...

Page 27: ...EFRIGERANT WHEN BELOW CURVE R8GE X36C X48C X60C Charging Chart Cooling Figure 13 Charging Chart for 3 Ton Units 3 5 TON MODELS 4 TON MODEL 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 5...

Page 28: ...Has the owner s information been reviewed with the customer YES NO Has the Literature Package been left with the unit YES NO ELECTRICAL SYSTEM Electrical connections tight YES NO Line voltage polarity...

Reviews: