4.2.3 Device Status Page
-> Num Bands : 2
Current Band : 2
Band Switch : ENABLED
Actual Current : 155
Lower Warning : 110
Upper Warning : 190
Lower Limit : 100
Upper Limit : 200
The
Device Status Page
lists information about the specified device. Information about other
devices can be seen by pressing the
Next
or
Previous
buttons.
PARAMETER
DESCRIPTION
ACCESS
Range
Num Bands
Number of LNB bands. This value is set
to 1 for single band LNBs.
Read-write
1 to 4
Current Band
Current ULC band
Read-only
1 to 4
Band Switch
ENABLED if the LNB is multi-band.
DISABLED if the LNB is single band.
Read-only
-
Actual Current
Current consumption in mA for the
selected device
Read-only
-
Lower Warning
Lower warning threshold for LNB
current. If LNB current is below this
value, a warning will be triggered.
Read-write
0 to 500
Upper Warning
Upper warning threshold for LNB
current. If LNB current is above this
value, a warning will be triggered.
Read-write
0 to 500
Lower Limit
Minimum LNB current before an
undercurrent fault is triggered
Read-write
0 to 500
Upper Limit
Maximum LNB current before an
overcurrent fault is triggered
Read-write
0 to 500