SNMP Settings
PARAMETER
DESCRIPTION
ACCESS
Range
Trap Activated
Non-zero if traps should be
generated when a condition occurs
Read-write
0 or 1
Trap Cycles
Approximate time between sending
or repeating traps. Accepted values
are either 0 or >=15. Value 0
means to send a trap only once per
occurrence.
Read-write
0 or >=15
Trap On Device1 Fault
Non-zero for the device to send
SNMP trap due to a Device 1 fault
Read-write
0 or 1
Trap On Device2 Fault
Non-zero for the device to send
SNMP trap due to a Device 2 fault
Read-write
0 or 1
Trap On Power Fault
Non-zero for the device to send
SNMP trap due to LNB Power fault
Read-write
0 or 1
Device Config
PARAMETER
DESCRIPTION
ACCESS
Range
Max Current
Maximum LNB current before an
overcurrent fault is triggered
Read-write
0 to 500
Min Current
Minimum LNB current before an
undercurrent fault is triggered
Read-write
0 to 500
Upper Warning
Upper warning threshold for LNB
current. If LNB current is above this
value, a warning will be triggered.
Read-write
0 to 500
Lower Warning
Lower warning threshold for LNB
current. If LNB current is below this
value, a warning will be triggered.
Read-write
0 to 500
Ulc Status
0 = ULC Disabled, 1 = ULC Enabled
Read-write
0 or 1
Lnb Bands
The number of supported multiband
LNB bands (max 4). For single band
LNBs, this value will be set to 1.
Read-write
1 to 4
Device Model
The model of the LNB model used. If
this device is not a Norsat LNB, it shall
be initialized to "UNKNOWN".
Read-only
-
Factory Reset
Factory Reset. Write 1 to trigger a
factory reset of the Redundant Switch.
Read-write
1