Instruction Sheet
P/N 1029715A
Manifold Service Kit - P/N 1028309
Use this service kit to replace the manifold O-rings on any ProBlue
t
adhesive melter.
WARNING: Risk of personal injury or equipment damage! Refer to
the safety information provided in the melter manual before servicing
the melter. Failure to comply with the safety information provided
can result in personal injury, including death.
Required Tools:
4-mm hex wrench
6-mm hex wrench
5
/
16
in. open-end wrench (2 required)
P/N 942080
P/N 1019515 (Three)
Parker Lubricant
P/N 941161 (Two)
P/N 942111
3.
Disconnect all hoses from the manifold.
2.
Relieve the system hydraulic pressure. Refer to the
melter product manual for information on relieving hydraulic
pressure.
1.
Operate the melter and discharge hot melt until the
tank is empty.
Note:
Reduce the speed of the pump to
fully empty the tank.
6.
Open the filter access door, and then
remove the top panel, the air filter, and the
back panel.
Prepare the Melter
WARNING: Risk of electrocution! The manifold heater terminals
carry high voltage. Before removing the back panel, ensure that
power to the melter is disconnected at the local power disconnect.
Failure to properly disconnect power from the melter can result in
personal injury, including death.
4.
Switch the melter off.
5.
Disconnect power to the melter at the local power
disconnect switch.