LA 404 Pattern Control System
55
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
System Settings 3
This setup menu is used to configure the remote enable and the trigger
clipping function.
If remote enable is set to ACTIVE then an external contact closure is
required on the remote input plug to activate pattern generation.
Clipping inhibits the pattern output if the product length measured by the
photosensor is shorter than the programmed pattern for a specific channel.
This feature is typically used to prevent glue from dispensing on skewed
products. When pattern clipping is detected a warning is displayed in the
Warnings
screen, and the warning relay is activated.
+SK:?A!+?::;<JK!/
,?A6:?!X<=^F?!!!!!%G$".X!
!
GF;>>;<J!!!!!!!!!!-MM
6640032A
1. To set remote enable:
a. Press the
%
or
&
button for the cursor to appear beside ACTIVE.
b. Press the
"
or
#
button to ACTIVE or INACTIVE.
When set to ACTIVE, make sure you have:
$
connected the plug provided in the ship-with kit to the
Remote
Input
connector, refer to
Remote Enable Plug
given earlier in the
manual
.
$
wired the 24 VDC (
Remote Input
plug, pin 1) to the enable input
(
Remote Input
plug, pin 7) using an electrically isolated contact,
refer to
Remote Enable Plug
.
$
To
bypass this function, set Remote Enable parameter to
INACTIVE.
2. To set clipping:
a. Press the
%
or
&
button for the cursor to appear beside On/Off.
b. Press the
"
or
#
button to On/Off.
Summary of Contents for LA 404
Page 28: ......