LA 404 Pattern Control System
34
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Normal Beads
(contd)
1. To set Dly (delay):
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to to set the desired delay value from
0 – 8187 mm.
2. To set Dur (duration, also called length):
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to set the desired duration value from
0 – 8192 mm.
NOTE:
This menu screen automatically adjusts the start of successive
intervals during setup to prevent overlapping of bead. When incrementing
delay or duration settings, the bead editor will stop at the overlap value. To
continue incrementing delay or duration settings, release and press the
"
button.
Next Product
Leading
Edge
Bead 2
Gun
Trigger
Gun-to-
trigger
offset
(GTO)
Leading
Edge
Direction of Travel
Dur 1
Dly 1
Direction of Travel
Dur 2
Dly 2
Bead 1
6640037A
Figure 7
Bead Patterns
To Delete a Bead
1. Press the
%
or
&
button for the cursor to appear beside Dur 1 – 4.
2. Press and hold the
#
button, the numeric value will decrement to 1
(one).
3. To delete, release and press the
#
button again for the numeric value to
go down to zero. The bead will be replaced by the subsequent bead.
Summary of Contents for LA 404