LA 404 Pattern Control System
30
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Pressure 1 and 2 Settings
(contd)
45?KK85?!1!+?::;<JK
+>??7!1
@
!
!
!!!41!!!!@N
+>??7!2
/!!!!!42!!!!O@N
*;<!@N
!*=P!!!1@@N
6640012A
1. To set speed 1:
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to set the desired speed value from
0 – 599 m/min.
2. To set P1:
a. Press the
%
or
&
button for the cursor to appear beside P1’s
numeric percentage value.
b. Press the
&
button to set P1 from 0 – 100%.
3. To set speed 2:
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to set the desired speed value from
1 – 600 m/min.
4. To set P2:
a. Press the
%
or
&
button for the cursor to appear beside P2’s
numeric percentage value.
b. Press the
&
button to set P2 from 0 – 100%.
5. To set minimum and maximum pressure:
a. Press the
%
or
&
button for the cursor to appear beside either Min
or Max.
b. When the cursor appears beside Min, press the
"
or
#
button to set
the desired percentage value from 0 – 99%.
c. When the cursor appears beside Max, press the
"
or
#
button to
set the desired percentage value from 1 – 99%.
6. Press the SET UP forward button to go to Pressure 2 Settings, and then
repeat steps 1 – 5.