System Positioning and Mounting
Flow Direction
The dryer must be positioned so that can ends pass through it in the correct
direction. When moving the dryer into position in the production line, note
the position of the motion sensor head. This is the dryer entrance. A flow
direction arrow is also located inside the coil tray.
NOTE:
Optional magnetic separators are always installed at the exit end of
the dryer.
Clearances
Provide clearances around dryer as follows:
S
Make sure blower intake (filters) and vents are not obstructed.
S
Provide 1 meter (39 in.) of space at the rear of the dryer to remove the
access panel for power and interlock connections and repairs.
S
Provide 1 meter (39 in.) of space in front of the dryer to open the
enclosure doors.
Mounting and Line Connections
The dryer legs are set at the factory to approximately the height listed on
the customer approval form supplied with the purchase order. Level the
dryer and bolt it to the floor.
See Figure 7. Six evenly spaced
1
/
4
−
20 NCB threaded holes are provided
in the dryer exit and entrance hubs. Secure your can end rod cages or
trays to the entrance and exit hubs as required.
CAUTION:
Do not apply excessive force to the hub assemblies. The
ancillary track work or rod cage assemblies must carefully fitted to prevent
applying strain to the hubs, which will be transmitted to the glass coil tube
and cause the tube to fracture.