Safety Enclosure for Automated Dispensing Systems
Service
Component
Recommended Interval
Action
Electrical box
As needed based on the
operating environment
Remove dust and debris from inside the electrical box.
Light curtain system Every six months
Verify the following:
The light curtain response time is normal.
The light curtain mounting bracket screws are secure.
No modifications were made to the light curtain system.
The safety enclosure installation has not been changed or
damaged.
The safety relay inside the electrical box is free from oil or
dust accumulation that could interfere with conductivity.
The wiring connections to the safety relay inside the
electrical box are secure, with no loose or damaged wires.
NOTE:
Refer to the manufacturer’s product manuals for
additional information on light curtain and safety relay
maintenance.