11
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Safety Enclosure for Automated Dispensing Systems
Installation
Use this section in tandem with the Quick Start Guide and the valve system manuals to install all components of the
system.
You will need the following items:
• Pallet jack
• Open-end wrench set
• Adjustable open-end wrench
• 4 mm and 5 mm hex keys
• (Vision systems only) Four M4 x 12 screws to install the monitor
Unpack the System Components and Install the Feet
1.
Remove loose items from inside the enclosure (feet, articulating arm, keyboard tray, and loose hardware).
2.
Carefully remove the enclosure and stand it upright.
3.
Use a pallet jack to lift a corner of the enclosure
and then use an adjustable open-end wrench to
install the feet. Repeat to install the remaining
feet.
(Vision Systems Only) Install the Monitor and Keyboard
1.
Install the articulating arm on the mounting base.
2.
Install the keyboard tray on the articulating arm.
3.
Use four (4) M4 x 12 screws (customer-supplied)
to secure the monitor to the monitor mounting
plate.