3.2
Technology unit overview
BU 0500 GB
Subject to technical alterations
43
3.2.1 SimpleBox, SK CSX-0
This option is used as a simple parameterisation, display and control tool for the
frequency inverter SK 5xxE. With this, even in active BUS operation, data can
be read out and parameterisation made especially if the frequency inverter slot
is occupied with a BUS unit.
Features
•
4-digit, 7-segment LED display
•
Single button operation
•
Display of the active parameter set and operating values
After the SimpleBox has been attached, the cable connectors plugged in and
the mains has been switched on, horizontal lines appear in the 4-digit 7-
segment display. This display signals the operational readiness of the frequency
inverter.
If a jog frequency value is pre-set in parameter P113, or a minimum frequency
is pre-set in P104, the display flashes with this value.
If the frequency inverter is enabled, the display changes automatically to the
operating value selected in parameter >Selection Display value< P001 (factory
setting = current frequency).
The actual parameter set is shown by the 2 LEDs next to the display on the left
in binary code.
NOTE
Settings should only be implemented by qualified personnel, strictly in accordance with
the warning and safety information.
Installation
The SimpleBox can be attached to any technology unit (SK TU3-…) or to the blind cover. To remove it, simply
pull it off after the RJ12 connection has been detached (press in the latching lever on the RJ12 connector).
Connection
The SimpleBox is connected to the socket at the upper edge
of the frequency inverter using the RJ12 connector/cable.
If necessary DIP switch 1 (left) can be used to activate a
BUS connection resistor for the RS485 interface. This may
be necessary if the frequency inverter is to be connected to
an overriding control unit from a great distance.
Further details can be found in Section 2.9.1.
Top side of device
RJ12
2 x RJ45, only with
SK 52xE / 53xE
X11
X10 X9