7.7.1 Mounting the external heat sink kit:
Before installing the device, please make certain that the walls of the control cabinet can bear the load.
An opening in the wall of the control cabinet, with the dimensions of the supplied heat sink is necessary for the
installation.
1. The heat-conducting paste must be applied to the SK 5xxE ColdPlate version.
2. The heat sink must be mounted on the frequency inverter using the screws supplied.
3. The screws must be tightened and any excess heat-conducting paste must be removed.
4. Place the seal between the frequency inverter and the wall of the control cabinet.
5. The assembled device is inserted through the opening in the wall of the control cabinet.
6. Fix the frequency inverter to the wall of the control cabinet with all of the screws.
(Drilling template, see Section 2.3.2)
If correctly installed, the device is now ready for use.
NOTE:
If correctly installed, protection (from outside) of max. IP54 exists.