14
4. MAXIMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red
progress lights turn on. Initial MAXIMUM ANGLE value will be MINIMUM ANGLE plus 4%. Maximum
angle value can be set to any value greater than MINIMUM ANGLE by pressing
UP
/DOWN
buttons. Once desired value has been set, press
ENTER
button
.
5. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP
/DOWN
buttons to increase/decrease batch count. Mode Count increases each time target angle is
reached if a batch count of zero is entered. Mode Count is displayed as 01ofXX if a non-zero batch
count is entered and resets to 01 after batch count completed. Once desired value has been set, press
ENTER
button
.
6. PSET target screen is displayed labelled with next available PSET number from 01 to 10.
7. To enter additional angle pre-sets, repeatedly press
ENTER
button
until target angle screen is
displayed and repeat steps above.
Editing a Pre-set
Edit PSET function gives user ability to edit stored PSETS on wrench.
1. From Pre-set screen to be edited, press and hold
UNITS
U
button
for 3 seconds.
2. CHANGE PRE-SET screen is displayed.
3. Highlight
EDIT
selection using
UP
/DOWN
buttons then press
ENTER
button.
4. MINIMUM TORQUE or ANGLE screen is displayed. Value can be changed by pressing
/DOWN
buttons. Once desired target torque or angle value has been set,
press
ENTER
button
.
5. MAXIMUM TORQUE or ANGLE screen is displayed next. Value can be changed by pressing
/DOWN
buttons. Once desired target torque or angle value has been set, press
ENTER
button
.
6. BATCH COUNT screen is displayed next. Value can be changed by pressing
UP
/DOWN
buttons.
Once desired batch count value has been set, press
ENTER
button
.
7. PSET target screen is displayed labelled with same PSET number.