NORAM 65ET GRADER
4-27
Lubrication and Maintena
nce - Grader Compon
ents
4
Every 500 Hours or 3 Months
Hydraulic Oil Strainers - Clean
Two strainers, a filler strainer and suction strainer, are used in the hydraulic system. Clean strainers
when the filter element is changed and the hydraulic tank is drained.
1. Remove fill cap to release pressure
(1)
.
2. Remove bolts
(2)
attaching the filler strainer
(3)
to
the oil tank. Carefully remove cover and o-ring from
top of tank. Discard o-ring.
NOTICE:
Clean hands before and after inserting in
hydraulic oil tank.
3. Clean strainer using a commercial, non-flammable,
non-toxic solvent. Use compressed air (limited to 207
kPa (30 psi) to blow-dry strainer. Blow air from inside
out.
4. Remove drain plug
(4)
and drain hydraulic oil from
tank.
5. Remove access cover
(5)
.
6. Clean suction strainer
(6)
using compressed air
(limited to 207 kPa (30 psi).
7. Flush tank.
8. Install new o-ring on fill cap cover. Attach fill cap
cover to oil tank and tighten bolts.
9. Fill hydraulic oil tank. Install fill cap and lock.
2
1
3
5
4
6
Summary of Contents for 65ET T4 FINAL
Page 2: ...This page intentionally left blank ...
Page 10: ...1 NORAM 65ET GRADER 1 6 Safety 1 Safety Decal Locations SAFETY DECAL LOCATIONS ...
Page 54: ...This page intentionally left blank ...
Page 78: ...This page intentionally left blank ...
Page 142: ...This page intentionally left blank ...
Page 164: ...This page intentionally left blank ...
Page 182: ...1 NORAM 65ET GRADER 7 18 Specifications 7 Options ...
Page 183: ...NORAM 65ET GRADER 7 19 Specifications 7 Options ...