44
5.5.
Hydraulics
Failure
Modes
Leaking
oil,
stuck
valves,
debris
in
components,
damaged
seals
from
installation
or
worn
out,
incorrectly
installed
fittings,
hoses
or
orifices,
failed
components.
Leaking
oil
near
the
NORAC
valve
block
1.
Inspect
the
fittings
and
O
‐
rings
on
the
pressure,
tank,
A
and
B
ports.
The
fittings
should
be
tightened
to
18
ft
‐
lbs
(24
Nm).
Proper
NORAC
seals
and
fittings
should
be
used.
2.
Inspect
the
valve
block
for
cracks.
3.
Check
the
components
in
the
valve
block
and
ensure
they
are
correctly
torqued
and
the
seals
are
not
damaged.