19
4.6 H
YDRAULIC
I
NSTALLATION
IMPORTANT:
From this point on in the installation the
booms will be inoperative until the
hydraulics are fully installed.
WARNING!
The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system. When
changing the boom hydraulic hoses leave
the booms in TRANSPORT POSITION.
IMPORTANT:
Component
failure
due
to
oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.
Depending on the valve block part
number, the A and B ports may be
reversed. Ensure that the orifices are
oriented properly for the A and B ports
or the system will not function properly.
4.6.1 Valve Assembly
1.
On a clean surface remove all plastic
plugs from the NORAC hydraulic Valve
(
V01
) (
Figure 19
).
44963D
44933D
Figure 19 – NORAC Valve Block
2.
Install the male adapters (
F02
) on the
"P" and "T" ports and tighten to 18 ft-
lbs.
3.
Install the orifices (
F01
) into the "B"
ports
with the notch facing outward
as
shown in
Figure 20
.
4.
Install the male adapters (
F02
) into the
"B" ports and tighten to 18 ft-lbs.
5.
Install the plugs (
F03
) into the "A" ports
and tighten to 18 ft-lbs.
Summary of Contents for UC4 Plus Rogator 1286C
Page 11: ...8 Figure 3 Hydraulic Plumbing Schematic ...
Page 16: ...13 Figure 9 Sensor Serial Number Installation Location 3 SENSOR SYSTEM 5 SENSOR SYSTEM ...
Page 31: ...28 5 3 ITEM C3 44656D CABLE VALVE VARIABLE RATE DT ...
Page 32: ...29 5 4 ITEM C10 44650 39 POWER CABLE GENERIC SELF PROPLELLED ...
Page 33: ...30 5 5 ITEM C11 44651 03 EXTENSION CABLE VALVE GENERIC ...
Page 34: ...31 5 6 ITEM C12 44658 32 CABLE INTERFACE UC4 DT06 2X GND2 ...