15
4.5.1
Boom Frame Roll Sensor
Mounting
1.
Use the supplied hardware to mount
the boom frame roll sensor (
E04
) as
shown in
Figure 18
.
When mounting the boom frame roll
sensor follow these guidelines:
a)
To prevent bending the bracket,
ensure bolts are placed as close
together as possible (minimize
C
in
Figure 18
).
b)
Be sure to use the roll sensor
without the temperature probe
(
E04
).
c)
When the boom is centered (not
rolled over) the roll sensor should
be level with respect to the sprayer
chassis.
d)
It is best to mount the roll sensor to
the left hand trapeze link (when
looking from the rear of the
sprayer).
e)
The roll sensor AMP (circular)
connector
MUST exit towards
the right hand wing
(when
looking from the rear of the
sprayer).
Figure 18: Boom Frame Roll Sensor
Mounted to a Trapeze Link
2.
Cable-tie the sensor connector to the
frame with enough slack to allow the
link to rotate.
Make sure the bracket does not
collide with any parts of the
sprayer when the boom rotates.
Also ensure there is enough slack
to allow the roll sensor to rotate.
Summary of Contents for UC4+ Apache 1010 2005+
Page 9: ...6 Figure 3 Hydraulic Plumbing Schematic ...
Page 27: ...24 5 ELECTRICAL REFERENCE CABLE DRAWINGS 5 1 ITEM C02 44668 CABLE SENSOR BRANCH ...
Page 28: ...25 5 2 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 29: ...26 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 30: ...27 5 4 ITEM C05 44674 CABLE UC4 SENSOR ROLL BIAS ...
Page 31: ...28 5 5 ITEM C10 44650 39 CABLE POWER GENERIC SELF PROPELLED L 100 2 54m ...
Page 32: ...29 5 6 ITEM C11 44651 03 CABLE VALVE EXTENSION GENERIC 365 9 27m ...
Page 33: ...30 5 7 ITEM C12 44658 18 CABLE UC4 VALVE AP2 MAIN ...
Page 34: ...31 5 8 ITEM C13 44658 17 CABLE UC4 SENSE AP2 ...
Page 35: ...32 5 9 ITEM C14 44658 99 CABLE UC4 INTERFACE POWER PIGTAIL FUSED ...