4.5
R
OLL
S
ENSOR
I
NSTALLATION
Mount the roll sensors to the included roll
sensor brackets using the machine screws
and nylon lock nuts, as illustrated in
Figure
16
.
The roll sensors must be
mounted tightly to the brackets.
Figure 16: Mounting the Roll Sensor
to the Roll Sensor Mounting Bracket
When mounting the roll sensors, use the
following guidelines and refer to
Figure 17
.
a)
The intermediate frame roll sensor
must have the lowest serial number and
the chassis roll sensor must have the
highest serial number.
b)
The smaller the distance between
A
and
B
in
Figure 17
, the better the
performance will be.
c)
Ensure the roll sensors are sitting
relatively level when the sprayer chassis
and boom are level.
d)
All roll sensors must be mounted with
the circular AMP connector facing
towards the Right-Hand Wing (when
looking from the rear of the sprayer).
Figure 17: General Roll Sensor Mounting Location on a Trapeze Style Boom
Connectors towards
Right-hand Wing
Summary of Contents for UC4+ Apache 1010 2005+
Page 9: ...6 Figure 3 Hydraulic Plumbing Schematic ...
Page 27: ...24 5 ELECTRICAL REFERENCE CABLE DRAWINGS 5 1 ITEM C02 44668 CABLE SENSOR BRANCH ...
Page 28: ...25 5 2 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 29: ...26 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 30: ...27 5 4 ITEM C05 44674 CABLE UC4 SENSOR ROLL BIAS ...
Page 31: ...28 5 5 ITEM C10 44650 39 CABLE POWER GENERIC SELF PROPELLED L 100 2 54m ...
Page 32: ...29 5 6 ITEM C11 44651 03 CABLE VALVE EXTENSION GENERIC 365 9 27m ...
Page 33: ...30 5 7 ITEM C12 44658 18 CABLE UC4 VALVE AP2 MAIN ...
Page 34: ...31 5 8 ITEM C13 44658 17 CABLE UC4 SENSE AP2 ...
Page 35: ...32 5 9 ITEM C14 44658 99 CABLE UC4 INTERFACE POWER PIGTAIL FUSED ...