37
key beeps from the indicator. Parameters are 0 (off) or 1 (on) followed by the
[TARE] key. Error 32 will be displayed for an invalid entry.
80 Set Time
Time is set out side of calibration mode in normal weighing mode (you must
exit cal mode). This parameter allows you to set the battery backed real time
clock on the indicator. Pressing 80 followed by the [PRINT/SELECT] key will
display the current time on the display. To change the time, enter your new
time as HHMMSS followed by the [TARE] key. Example: to change the time
to 9 hours 33 minutes and 30 seconds enter 093330 followed by the [TARE]
key.
81 Set Date
Date is set out side of calibration mode in normal weighing mode. This
parameter allows you to change the battery-backed date on the indicator.
Pressing 81 followed by the [PRINT/SELECT] key will display the current
date on the display. To change the time, enter your new time as YYMMDD
followed by the [TARE] key. Example: to change the date to December 14
year 2001 enter 011214 followed by the [TARE] key.
8.9 SERIAL COMMUNICATIONS Parameters
30 baud rate for COM 1 (6)
Changes the baud rate for COM1. Valid parameters are 0-9. An invalid entry
will display error 52.
32 baud rate for COM 2 (6)
Changes the baud rate for COM1. Valid parameters are 0-9. An invalid entry
will display error 52.
0 : 150
1: 300
2: 600
3: 1200
4: 2400
5: 4800
6: 9600 (factory default)
7: 14400
8: 19200
9: 32400
9600 baud is the default baud rate for both ports.
Note: only a single COM
port can be used for printing.
31 Parity for COM 1 (0)
Changes the parity setting for COM1. Valid parameters are 0-2. An invalid
entry will display error 53.
0: No parity
1: ODD parity
2: Even parity.
33 Parity for COM 2 (0)
34 Stringmode for COM1 (99)