2.11 Connection of
ACTIVATION COMMAND
17 18 19 20 21 22 23 24 26
COM
COM
The connection of activation COMMAND can be provi-
ded with any push button or N.O. contact.If more devi-
ces are available connect in serial
In the paragraph 3.1 are described the different fun
-
ctions of each control.
Terminal:
21
OPEN
22
CLOSE
23
START
24
PEDESTRIAN
2.12 Connection of the TIMER
17 18 19 20 21 22 23 24 26
COM
COM
If you need a timer it is possible to connect it to the ter-
minal board no. 21 and COM. The contact of the timer
is normally open and it should be closed for all the time
that the gate is open.
If an opening command is con-
nected to terminal 21, it must be
connected in serial.
2.13 Connection of the LIGHT
24 V
24 V
COM
9 11
LIGHT 24 Vac
LIGHT 230 Vac
24 V
24 V
COM
6 7
If you prevue to use the photo-
test or the signal light, you cannot
use this connection.
8