12
5.4 Increasing the PAUSE time
The pause time can be increased without having to repeat the times learning operation. While the automation is in pause
mode, each time the push-button
P
is pressed the pause time is increased by 5 seconds. The level can be increased
four times. The fifth time the push-button is pressed, the pause time returns to the initial value. Therefore, it is possible to
increase the pause time by up to 20 seconds. If 20 seconds is not enough, it is possible to continue increasing the pause
time by performing another opening cycle.
Button P
Time variation each
time the button is
pressed.
+5”
+5”
+5”
+5”
Initial time
Led TEST
The operation can only be performed when the
automation is in pause mode during opening.
5.3 Activate the
LAMP
in the
PAUSE TIME
During this operation OPENING CONTROL ( START) is possibile to activate the lamp during the pause time.
WARNING! This operation is possibile only when
the PARTIAL OPENING CONTROL is connected
to the terminal board no.24 or to a remote control
When the gate is opening ( START) is sufficient to give a PARTIAL
OPENING COMMAND from the terminal no.24 or remote control. You
can deactivate this function repeating the learning time process for
the OPENING command without the partial opening.
5.5
ACCESS CONTROL FUNCTION
The access control function has the following logic:
-
OPEN:
If the intervention is from the closing photocell, the gate open until
two seconds when the photocell get free and it renverse when closing.
-
CLOSED:
In case of intervention of the closing photocell, the gate opens and after tow seconds when the gates is free,
it renverse for two seconds.
- In
PAUSE TIME
the intervention of the photo-beam is 2 seconds after the pause time.To activate or deactivate the AC-
CESS CONTROL make as follow
ACTIVATION:
During the START learning command, interrupt the clo-
sing photocell while the gate is opening or in pause
DEACTIVATION:
During the START learning command don’t interrupt any
photocell
The control unit has an obstacle detection. In case that the gate
has an obstacle , the obstacle detection will stop the motor. It is
possible to adjust the sensitivity of the obstacle detection with the
trimmer.
To increase the sensitivity turn in the clock-wise ( the motor will
stop easily) and in the other side to reduce the sensitivity.
WARNING!! The control will not working for the first 2 seconds.
WARNING!! BEFORE ADJUST A LOW SENSITIVITY
BECAUSE A HIGHER CAN STOP THE MOTOR
(for example in case of low temperature or friction)
even if the run hasn’t been stopped.
Low
sensitivity
High
sensitivity
5.6 Adjustment of the OBSTACLE DETENCTION
For the correct use of the fol-
lowing function you have to
install a couple of photocell as
shown in the paragraph 2.6
The control unit dispose of a jumper JP2 which
can cancel the obstacle detectoin and you can set
up the jumper as follow:
JP2
Activate the obstable
detection
JP2
Exclude the obstacle
detection