6
2.4 Connection of a
MECHANICAL BRAKE
2 3 4 5 6
Put in
ON DIP4
as shown in the picture, in case an automatic brake is connected in the terminal 15-16.
15 16
2 5 6 7 6
2 5 6 7 6
Use DIP 6 to setting up the brake:
Put the
DIP6
in
ON
if the brake is activated
when the brake is powered
Put the
DIP6
in
OFF
if the brake is activated
when it is not powered
2.5 Connection of the
LIMIT SWITCHES
Here is the connection of both limit switches. Even if the working time can be programmed, it is necessary to use
the limit switches
17 18 19
MOT 1
OPEN
CLOSE
The contacts of the limit
switches are normally
closed (N.C.)
24 V
24 V
COM
COM
2.6 Connection of the
PHOTO-BEAMS without TEST
The photocell receiver contact must be:
-
clean
(insulated from power supply voltages)
-
N.C. type
(normally closed).
If more than one pair of photocells is used, they must
be connected in series.
If the PHOTO input is not used,
make a link between terminal
board 20 and COM.
POWER SUPPLY TO
TX PHOTOCELLE
POWER SUPPLY TO
RX PHOTOCELL
17 18 19 20
24 V
24 V
COM
COM
Photocell receiver.
N.C. contact terminals