START-S11
Technical manual
-28-
Set
up Description
Val. Accepted
Standard Memo
T 01
Opening time MOT1
from 2 to 127,5 s
15 s
T 02
Closing Time MOT1
from 2 to 127,5 s
15 s
T 03
Opening time MOT2
from 2 to 127,5 s
15 s
T 04
Closing Time MOT2
from 2 to 127,5 s
15 s
T 05
Position of the slow down MOT1 opens
(advanced sec)
from 2 to 127,5 s
2 s
T 06
Position of the slow down MOT2 opens
(advanced sec)
from 2 to 127,5 s
2 s
T 07
Position of the slow down MOT1 closes
(advanced sec)
from 2 to 127,5 s
3 s
T 08
Position of the slow down MOT2 closes
(advanced sec)
from 2 to 127,5 s
3 s
T 09
Desplacement time OPENS
from 2 to 127,5 s
2 s
T 10
Desplacement time CLOSES
from 2 to 127,5 s
2 s
T 11
Pause Time for START command
from 2 to 127,5 s
10 s
T 12
Opening Time MOT1 PARTIAL OPENING
from 2 to 127,5 s
8 s
T 13
Closing Time MOT1 PARTIAL OPENING
from 2 to 127,5 s
8 s
T 14
Pause Time for PARTIAL OPENING
from 2 to 127,5 s
10 s
T 15
Pre-lighting time when the gate is closes
from 0 to 10 s
2 s
T 16
Pre-lighting time when the gate is open
from 0 to 10 s
2 s
T 17
Electrical key Lock
from 0 to 10 s
2 s
T18
Courtesy Light
from 0 to 255 s
120 s
T 19
Reversing Stroke
(0 to disable)
from 0 to 10 s
0 s
T 20
Motor Starting MOT1
(When the motor is starting,
the obstacle detection is not activated)
from 0 to 10 s
2 s
T 21
Motor Starting MOT2
(When the motor is starting,
the obstacle detection is not activated)
from 0 to 10 s
2 s
T 22
Delayed obstacle detection in cent. sec.
from 5 to 200
0.30 s