1
With buttons
P1, P2
and
P3
go to the function
C03.
2
Press
P1
to confi rm
3
To cancel the operation press
P1
in
10
seconds againt.
Otherwise you have to wait.
4
Reset successfullt done!
START-S11
Technical manual
-25-
This operation cancel all codes previously memorized. If you need to cancel one single code, see next chap-
ter. The cancellation of the memory is possible only when the gate is
CLOSED
.
If you bring
S08
on 1, the control unit will accept
only HCS codes and it will control the rolling code
counter. The remote controls cannot be copied. If
the rolling code counter is not activated, it will ac-
cepted only the fi xed part of the code.
8
Remote Controls MANAGING
This receiver can manage standard codes from 12 till 64 bit and rolling codes HCS©. The fi rst learned trans-
mitter establish the code’s type taht the receiver has to manage, it means that the transmitter has to have the
same code’s type. Concerning the rolling codes it is possible to activate or disactivate the key’scontrol and
the rolling counter. With this function you can choose the security level of the receiver.
8.1
CANCELLATION of the MEMORY CODE
8.2
ROLLING CODE activated
we recommend to cancel the memory before the memorization
of the fi rst remote control, this to be sure that no other codes are inside.
!
c 03
P1 confi rm
P110
----
S 08
ROLLING CODE
COMPLETE
1 - Activated
0 - Deactivated
(Standard)